北京pk10滚雪球在线计划

Build standard library
| 建筑 | 暖通空调 | 城市规划 | 结构 | 给排水 | 道路桥梁 | 电气 | 消防 All Majors | Building | HVAC | Urban Planning | Structure | Water Supply and Drainage | Roads and Bridges | Electrical | Fire Protection
| 建筑 | 结构 | 给排水 | 电气 | 暖通空调 | 道路桥梁 | 消防 All Majors | Building | Structure | Water Supply and Drainage | Electrical | HVAC | Road Bridge | Fire
| 住宅 | 别墅 | 办公 | 商业 | 医疗 | 教育 | 宾馆 | 文娱 | 交通 | 工业 | 景观 | 模型 Home | Residential | Villa | Office | Commercial | Medical | Education | Hotel | Culture | Transportation | Industrial | Landscape | Model
  • This project is a professional construction drawing of a 39 # villa building, structure, electrical, HVAC, water supply and drainage, with a total construction area of 474.13 square meters, 3 floors above ground, and a height of 12.35 meters; the contents of the drawings include: architectural specialty, general instructions for the design of construction drawings 、 Indoor and outdoor decoration construction method table, first floor plan, second floor, third floor, roof plan, building elevation, section view, wall sample, kitchen and bathroom sample, stair sample, general sample, door and window Large-scale drawings, windows and doors tables, large-scale drawings of balustrade facades; professional structure, general structural design instructions, basic floor plans, basic cross-section size tables, large samples connecting the foundation and the beam, the top of the foundation ~ one-story floor column construction method Plan, one-story floor to two-story floor column flat construction drawing, two-story floor to three-story floor column flat construction drawing, three-story floor to roof column flat construction drawing, first floor, second floor, Three-story, roof structure plane layout and slab reinforcement diagram, beam flat construction drawing, wall sample, stair reinforcement diagram, stair construction general diagram and description, reinforced concrete beam reinforcement plane representation explanation; electrical specialty, electrical construction General design instructions, legends and Material table of main equipment, system diagram of distribution box, large-scale drawings of building lightning protection contacts, first floor, second floor, third floor electrical floor plan, first floor, second floor, third floor, lightning protection ground plan, roof lightning protection plan; warm General, ventilation and air conditioning design and construction general instructions, equipment list, first, second, and third floor air-conditioning floor plans; water supply and drainage professional, indoor water supply and drainage construction drawing design general instructions, water supply pipe system details, drainage pipe system details, first Floor, second and third floor water supply and firefighting floor plans, first floor, second and third floor drainage floor plans, etc., as well as air conditioning configuration tables, structural foundation calculation books, stairs calculation books, etc.
  • The construction drawings (including calculation books, energy-saving design tables, and engineering survey report tables) of a low-level kindergarten, including a transmission room, the seismic fortification intensity is 7 degrees, and the main structural form is a frame structure. Among them, the building height of the kindergarten is 12.3 meters (height from the outdoor floor to the roof layer), and the number of floors above ground is 3; the building height of the transfer room is 4.2 meters (from the height of the outdoor design ground to the roof), and the number of floors above the ground is 1; the total construction area It is 8765 square meters (including 65 square meters of transmission room). The floor area ratio is 0.82, the building density is 28.5%, the greening rate is 35%, and the number of motor vehicle parking spaces is 28. The contents of the drawings include: building description, building energy-saving design, general plan, floor plan, elevation, section, staircase detail, dining ladder detail, toilet detail, node detail; water supply and drainage instructions, outdoor water supply and drainage, and Firefighting general plan, outdoor rainwater general plan, outdoor sewage general plan, water supply and drainage and fire hydrant plan self-spraying plan, water system schematic, solar system schematic, domestic sewage, wastewater system schematic, rainwater system schematic, air conditioning condensate system Schematic diagram, automatic sprinkler system schematic diagram, fire hydrant water supply system schematic diagram, water supply and drainage large-scale diagram, socketed engineering plastic pipe strip foundation diagram and concrete package diagram; structural description, general description and detailed drawings of the envelope structure, Schematic layout of the envelope structure, pile plan, foundation plan, flat construction drawing, reinforcement diagram, staircase detail, node detail diagram, schematic layout of the envelope structure, general description and details of the envelope structure; electrical instructions, Automatic fire alarm instructions, electrical floor plan, power distribution system diagram, fire floor plan, fire alarm system schematic diagram, power distribution Line system diagram, power distribution system diagram, power distribution plan, power distribution plan, lighting plan, roof lightning protection plan, ground plan, sub-metering, electrical fire, fire door, fire power monitoring system, kitchen Electrical floor plan; HVAC description, ventilation floor plan; landscaping description, planting design description, arbor planting plan, shrub planting plan, vertical design plan, paving and park road details, standard parking space details, sketch plan; decoration Description, floor plan, ceiling layout, floor layout, ceiling size, luminaire size, partition wall size, elevation index, elevation, node sample, etc. Specialties include architecture, structure, water supply and drainage, electrical, heating and ventilation, landscape greening, decoration, and foundation pit maintenance.
  • A full-scale professional construction drawing of a low-rise farmer's market, the seismic fortification intensity is 7 degrees, the main structural form is a frame structure, the building height is 12.15 meters, the number of above-ground floors is 1, the number of underground floors is 1, and the total construction area is 5347.18 square meters. The contents of the drawings include: architectural description, general plan, plan, elevation, section, enlarged plan of stairs, large-scale drawings of doors and windows; water supply and drainage instructions, plans, fire pump room and fire pool piping, self-spraying plans, large-scale bathroom Diagrams and system diagrams, water supply and drainage system diagrams; structural description, basic floor plan, reinforcement plan, flat construction drawing, structural floor plan, grid positioning diagram; electrical description, box-type substation system diagram, vertical Power distribution trunk map, power distribution box system diagram, power well layout sample map, fire control room layout sample map, grounding plan, power plan, roof lightning protection plan, lighting plan, automatic alarm and fire linkage control system diagram, video Monitoring system diagram, comprehensive wiring system diagram, elevator operation control system diagram, fire alarm plan, weak current plan; HVAC instructions, air-conditioning ventilation plan, ventilation plan. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • This project is a professional construction drawing of a rail transit signal intelligent power industrialization project plant, dormitory, office and gatehouse, pump room building, structure, electrical, HVAC, water supply and drainage. Its dormitory construction area is 2500 square meters, 4 floors above ground. Partial 5 storeys, 16.2 meters high, frame structure; office building, building area 3561 square meters, 4 floors above ground, 16.2 meters high, frame structure; factory building, building area 13,048 square meters, 3 floors above ground, 16.2 meters high, frame structure; Gatehouse, construction area 33 square meters, one floor above ground, 2.8 meters high, brick-concrete structure; pump house, construction area: 25 square meters above ground, 73 square meters underground, building floors: one above ground, one underground 3.3 meters, frame structure. The contents of the drawings include: architectural majors, general floor plans, outdoor engineering general floor plans, outdoor engineering fence vertical sections, construction practice tables, fire protection design articles, construction design instructions, vertical sections, exterior eaves details, stairs details, Detailed drawings of the bathroom, detailed drawings of the elevator in the building; structural specialty, general description of structural design, instructions for the design and construction of prestressed concrete pipe piles in the plant and office building, general instructions for the design of the steel structure of the factory building, beam plan, plate plan, pile plan, foundation plan, foundation details Plans, column plan views, staircase details, exterior eaves details, beam reinforcement drawings, foundation details, structural plans; electrical majors, electrical construction drawing design instructions, legends and weak current system diagrams, electrical system diagrams, lighting plans, socket plans , Fan coil plan, automatic fire alarm and weak current plan, ground plan, lightning protection plan, electrical plan; HVAC specialty, HVAC design and construction instructions, equipment table and large-scale drawings, air-conditioning duct plan, air-conditioning water duct plan, General plan of heating, schematic diagram of direct-fired engine room takeover, ventilation plan, direct-fired engine room Schematic diagram of cooling tower, air-conditioning ventilation plan, electrical general plan, lighting general plan; water supply and drainage specialty, water supply and drainage design and construction instructions, sewage pipeline longitudinal section view, water supply, reclaimed water, outdoor fire protection and sprinkler pipeline plan, outdoor pipeline comprehensive plan, Sewage pipeline plan, rainwater pipeline plan, toilet plan, water supply and drainage and firefighting plan, fire hydrant system plan, water supply and drainage system plan, roof water tank room detailed plan, water supply and drainage plan, sprinkler plan, etc.
  • Multi-professional construction drawings (including project list and project electrical inventory form) of a three-phase and one-phase project of a cloud data center, including data room, comprehensive building and fire tank. The seismic fortification intensity is 7 degrees for category B, and seismic measures are adopted according to 8 degrees for category B. The main structural forms are divided into a data room, a comprehensive building with a steel frame structure, and a fire-fighting pool with a cast-in-place reinforced concrete frame structure. Among them, the building height of the data room is 13.2 meters, the number of floors above the ground is 1,200, and the total building area is 23,200 square meters. The building height of the comprehensive building is 6.95-20.8 meters, the number of floors above the ground is 1, and the total building area is 1,655 square meters. The building height is 4.6 meters, the number of above-ground floors is 1 and the number of underground floors is 1. The total construction area is 736 square meters. The contents of the drawing include: general plan, vertical layout, road plan, green layout, earthwork balance, cable routing location map, transmission pipeline location map, building description, floor plan, elevation view, section view, detailed stairs, toilet Detailed drawings, large-scale wall drawings, detailed node drawings; water supply and drainage instructions, gas fire extinguishing system design and installation instructions, fire water supply and drainage construction drawings, fire hydrant system drawings, water supply and drainage, fire protection, fire hydrant floor plans, large bathroom drawings, high level Fire fighting water tank system schematic diagram, gas fire extinguishing system action control flow chart, rainwater and condensate drainage system diagram, toilet water supply and drainage large-scale drawing, gas fire extinguishing startup pipeline connection diagram, sprinkler system schematic diagram, water sprinkler layout plan, gas Layout plan of fire extinguishing system; structural description, layout of foundation plane, steel column, steel beam, horizontal brace, self-supporting floor slab layout and reinforcement diagram, purlin structure layout diagram, staircase detail standard section diagram, node detail diagram, Standard node diagram, wall structure layout diagram; electrical description, fire automatic alarm system design description, distribution Box system diagram, power trunk diagram, distribution box system diagram, power distribution, electrical, socket, emergency lighting, lighting, grounding, roof lightning protection floor plan, fire alarm system and floor plan, fire alarm control, electrical fire monitoring and very early Fire alarm system plan, fire alarm plan, gas fire extinguishing and linkage control plan, very early alarm plan, large-scale layout of TV wall; HVAC description, air-conditioning system schematic, air-conditioning system end schematic, machine room smoke exhaust schematic, exhaust Smoke system plan, heating plan, equipment floor plan, air-conditioning duct plan, smoke exhaust plan, ventilation plan, air-conditioning water plan, refrigerant tube, humidification tube, condensate tube plan, data machine room cross-sectional view, three-dimensional schematic diagram; decorative design instructions, Ground pavement map, integrated ceiling picture on the top, flat roof detail on the bathroom, node detail on the bathroom sink, step node detail on the liquid-cooled machine room, fire blocking on empty wall holes, fire blocking node on cable tray through wall holes ; Process description, schematic layout of the closed hot aisle, cable routing diagram, FIG first cabinet configuration system, locations, and sizes of holes through the wall schematic layout FIG cabinet, shelf power traces floorplan schematic arrangement grounding system, the bus is a schematic and small system like FIG. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation, decoration, and technology.
  • Multi-professional preliminary drawings of an energy station and its auxiliary projects (including calculation books, opinion reply sheets, amendment notices, process parts, outdoor pipe network projects), including pump rooms, 2, 4 # parent stations, and 3 substations. The seismic fortification intensity is 7 degrees, and the main structural form is a frame structure. Among them, the building height of the 2 # mother station is 3.45 meters, the height of the underground layer is 7.5 meters, the number of floors above the ground is 1 layer, the number of underground layers is 1 layer, and the total construction area is 1266.21 square meters; The number of floors is 1 layer, with a total construction area of 1807.3 square meters. The building height of the pump room is 28 meters, the number of floors above ground is 1 layer, the number of underground floors is 2 layers, and the total construction area is 1171.5 square meters. The contents of the drawings include: architectural instructions, floor plans, sectional views, stairwell elevations; water supply and drainage instructions, design instructions for fixed gas dry powder fire extinguishing systems, water supply and drainage plans, enlarged views of bathroom water supply and drainage, and water supply and drainage fire protection system schematic , Enlarged view of underground integrated equipment, enlarged view of roof fire water tank; structure description, raft foundation plane layout and reinforcement plan, wall and column layout plan, basement roof structure layout and panel reinforcement plan, basement roof beam Reinforcement plan, large-scale staircase plan; electrical description, power distribution system diagram, gas fire extinguishing system diagram, power plan, lighting plan, fire plan, ground plan, lightning protection plan; HVAC description, ventilation system plan; foundation pit support Description, floor plan of foundation pit support, elevation view, section view, steel flower tube soil nail making, soil nail and spraying surface layer connection, large-scale drawing of hanging net spraying, intercepting drainage ditch, water collecting well, safety fence, Large-scale drawings of drain pipes and monitoring points, floor plan of foundation pit monitoring; HVAC process description, energy station system schematic diagram, pipeline plan, Preparation plan, basic plan, section view, large-scale drawing, schematic diagram of water supply tank takeover; electrical process description, power supply and distribution system schematic, power distribution box system diagram, power control cabinet electrical primary system diagram, electrical floor diagram, grounding plan; automatic control process Description, general diagram of the network structure of the energy control system in the energy supply area of the energy station, point diagram of the automatic control system, schematic diagram of the energy-efficient PLC control cabinet, plan layout of the pipeline of the automatic control system, plan layout of the pipeline of the video monitoring and network telephone system, cable table of the automatic control system, General plan of laying outdoor optical cable pipelines in the energy supply area of energy stations, etc.
  • Hydropower construction drawings for public toilets in a town, building area: 74.7 square meters, building height: 4.65 meters, one floor above ground, structure type: brick-concrete structure. Contents include architectural design instructions, a list of building decoration practices, doors and windows, large samples, ground floor plans, roof plans, elevations, section views, floor plans for insulation layers, large wall samples, flat horse head walls, and large sections. Samples, large cornice samples and structural description, foundation plan, bulky top beams, slab reinforcement diagrams, layer beams, slab reinforcement diagrams, large beam samples, inclined roof beam heights and reinforcement indications, and slope roof slabs ’rebars Overlap large sample, roof inspection hole large sample, horse head wall standing, large section sample, cornice large sample and water supply and drainage instructions, water supply and drainage plan, bathroom water supply and drainage large sample map, water supply and drainage system schematic and electrical instructions, MEB general Schematic diagram of equipotential bonding, schematic diagram of partial equipotential bonding of LEB, system diagram of distribution box, wiring diagram of weak current distribution box, floor plan of toilet lighting, floor plan of toilet weak current, grounding plan.
  • A villa residential area project, including villa 1 # 3 floors above ground, 1 underground, building area of 767.32㎡, building height of 13.9m; 2 # building 3 floors above ground, 1 underground, building area of 666.97㎡, building height Is 13.69m; three-row row 1 #, 2 #, 6 # 3 floors above ground, 1 underground, building area is 1373.95㎡, building height 14.44m; four-row row 5 # three floors above ground, 1 underground, building The area is 1751.15㎡ and the building height is 14.44m. The six-row row 3 # and 4 # are 3 floors above ground and 1 basement, the building area is 2528.71㎡, the building height is 14.44m, 7 # ~ 10 # are 3 floors above ground and underground 2 floors with a building area of 2666.02㎡ and a building height of 14.44m; Shuangpin 1 # ~ 5 # 3 floors above ground and 1 basement floor with a building area of 1173.17㎡ and a building height of 13.9m; drawings include: architectural design instructions, Material practice table, vertical sectional view, door and window table and door and window detail drawing, staircase and toilet detail drawing, node detail drawing; structural design description, foundation plan layout drawing, column plan layout drawing, beam and plate construction method drawing, stair structure reinforcement drawing; Water supply and drainage design instructions, water supply and drainage trunk plan, water supply and drainage plan, system ; HVAC design instructions, heating mains plan, heating plan, system diagram; electrical design instructions and legends, main and ground plans, lighting, sockets, low-voltage pipeline reserve plans, roof lightning protection plans, power distribution system diagrams , Weak current system diagram
  • Fully professional construction drawing of a multi-story office building, the seismic fortification intensity is 8 degrees, the main structural form is a frame shear wall structure, the building height is 23.1 meters (including 1.5 meters indoor and outdoor height difference), the number of above-ground floors is 5, and the underground The number is 1 floor, with a total construction area of 8,467.58 square meters, of which the floor area is 6,934.70 square meters, and the underground construction area is 1,532.88 square meters. The contents of the drawings include: architectural instructions, green building design, floor plans, elevations, section views, large-scale drawings of stairs, large-scale drawings of walls, large-scale drawings of car ramps; water supply and drainage instructions, floor plans of water supply and drainage hydrant pipes, Floor plan of engine room, floor plan of fire pump room, sprinkler plan, water supply and drainage piping system, spray principle diagram, hydrant piping system diagram, fire pump room piping system diagram, pipe well riser layout; structural description, basic layout Floor plan, wall and column floor plan, reinforcement plan, staircase detail plan, canopy floor plan, canopy steel beam, short column plan, canopy rigid frame, steel column, support layout, canopy purlin layout Figures, details of canopy rigid frames, details of canopy nodes; electrical instructions, power distribution system diagrams, weak current system diagrams, distribution main plan, lighting plan, socket plan, weak current main plan, automatic fire alarm plan, public lighting plan , Roof lightning protection plan, foundation ground plan; HVAC instructions, green building design, ventilation plan, smoke exhaust schematic, etc. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • Fully professional construction drawings of multiple high-rise residential buildings in a community (including review reply sheet), including 1 ~ 8 # residential building, commercial S1 floor and basement. The seismic fortification intensity is 8 degrees. The main structural forms are divided into residential buildings and basement shear wall structures. The commercial S1 floor is a frame structure. Among them, the number of floors above the commercial S1 floor is 1 layer, the building height is 13.5 meters, and the building area is 1444.38 square meters; the number of floors above the 6 and 7 # buildings is 16 layers, the number of underground floors is 2 layers, and the building heights are 50 meters, the construction area is 9827.76, 8517.78 square meters; 3, 5, and 8 # are all 17 floors above ground, 2 underground floors, 50.3 meters building height, and building area of 8717.44 ~ 13056.1 square meters Meters; 1, 2, 4 # are 20 floors above ground and 2 floors underground, building height is 50.3 ~ 59 meters, building area is 8012.57 ~ 8012.57 square meters; basement is 1 underground, building The area is 25,543.89 square meters. The contents of the drawings include: building instructions, building design fire prevention chapter, green building design chapter, building energy saving design chapter, general plan positioning plan, floor plan, elevation view, section view, large-scale sample plan, floor elevator detail drawing, door Head detail, window well detail, wall detail; water supply and drainage instructions, drainage and firefighting plan, roof drainage plan, spray plan, water supply system diagram, hydrant system diagram, drainage system diagram, rainwater system diagram, sprinkler system Schematic diagram, large-scale plan of apartment water supply and drainage system, large-scale plan of apartment water supply and drainage system, large-scale image, large-scale drawing of fire water tank, schematic and detailed diagram of solar water heating; structure description, basic floor plan, wall column plan , Raft reinforcement plan, pile plan, floor plan, reinforcement plan, template plan, staircase detail, wall detail, ramp detail, secondary air defense entrance and exit detail, door frame wall detail, post-cast belt layout Figures, detailed drawings of frame columns and retaining walls; electrical instructions, seismic, energy-saving, and green building design instructions, strong electrical vertical trunk system diagrams, power distribution system diagrams, weak electricity system diagrams, automatic fire alarm system diagrams, electricity Detailed construction drawings, lighting plans, strong and weak mains power distribution plans, power distribution plans, fire alarm plans, weak current plans, roof lightning protection plans, foundation ground plans, electrical layout plans; HVAC instructions, green building design , Ventilation floor plan, Heating floor plan, Schematic diagram of pressurized air supply, smoke exhaust, heating system, large-scale drawing of heating and ventilation practices; decoration instructions, original floor plan, wall plan, floor plan, floor layout plan, ceiling layout plan, ceiling Dimensional drawings, lamp positioning maps, switch wiring diagrams, socket layout diagrams, elevation index diagrams, halls, overall sandbox area, negotiation area, bathroom access, planning department, reading bar, signing room / finance room, children's entertainment area, water Bar, reference room, conference room, general office, manager room, general office, property department, men's and women's façade, node diagram, etc. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation, and decoration.
  • Full-scale professional construction drawings of multiple high-rise residential buildings in a certain district (including the response to the review opinion), including 1 ~ 5 # residential buildings (4 # buildings are community supporting houses), S01 # community supporting houses and underground garages. The seismic fortification intensity is 7 degrees, and the main structural forms are divided into residential building shear walls and frame structures, community supporting houses are frame structures, and underground garages are slab-column seismic walls. Among them, the number of floors above and below the building # 1 are 32, the number of floors is 3 and 2, the building heights are 95.19, 96.6 meters (outdoor ground to the top of the daughter's wall), and the building areas are 34148.46, 16499.83 square meters. Meters; 2 ~ 4 # buildings have 6 floors above ground, 2 # 3 buildings have 3 underground floors, 4 # buildings have no underground floors, building height is 19.89-20 meters, and building area is 3261.26-16499.83 square meters ; S01 # Community supporting premises has 1 floor, building height is 5.1 meters, building area is 324.1 square meters; underground garage is 2 floors, building area is 16,652.02 square meters. The contents of the drawings include: building instructions, civil air defense engineering design instructions, green building design special articles, building energy saving design special articles, underground wartime floor plans, floor plans, elevations, section views, unit large-scale drawings, large-scale stairs, elevators Large-scale drawings, large-scale drawings of wall nodes, detailed drawings of civil defense, detailed drawings of doors and windows, large-scale drawings of car ramps, wartime and usual civil defense plans of underground garages; water supply and drainage instructions, water supply and drainage, firefighting plans, firefighting system diagrams, spraying Draining schematic diagram, drainage tank drainage, civil air defense water tank system diagram, water tank floor plan, water supply and drainage large-scale diagram, water supply system diagram, indoor cold and hot water system diagram, pipe well large-scale diagram, drainage system diagram, spraying Floor plan; structural description, civil air defense structure design description, special instructions for precast concrete laminated slabs, pile layout plan, foundation raft layout plan, detailed details of foundation members, reinforcement diagrams, flat construction drawings, structural floor construction drawings, roof floor trellis layout Plan, plan layout of horizontal member structure, component drawing, detailed drawing of stair reinforcement, construction drawing of professional leaving hole for plumbing, detailed drawing of foundation component, hidden column table; electrical Lighting, energy saving and seismic design instructions, civil air defense electrical design instructions, automatic fire alarm system design instructions, civil air defense system drawings, lighting floor plans, power floor plans, fire floor plans, foundation ground plans, electric well layouts, automatic fire alarm system drawings, Distribution main line diagram, weak current system diagram, emergency lighting system diagram, power distribution system diagram, electrical floor plan, electrical trunk plan, prefabricated roof electrical point positioning plan, top positioning plan, wall positioning plan, socket plan, weak current plan, Roof lightning protection plan; HVAC instructions, green building design, civil air defense design instructions and machine room plans, ventilation plans, heating plans, heating plans, large-scale drawings of plumbing wells, pressurized air supply schematics, heating and heating systems Figures and more. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • The construction drawing of a demolition and construction project of a low-level auxiliary kindergarten, the seismic fortification intensity is 6 degrees, and the main structural form is a frame structure; the building height is 12 meters, the number of floors above the ground is 3, and the number of underground floors is 1; the floor area of the kindergarten is 2627.2 square meters Meters, the basement area is 86.77 square meters, another fire fighting pool area is 113.05 square meters, and the gate guard and consumer control room above-ground construction area is 35.75 square meters. The contents of the drawings include: architectural design description, green building design description, building energy-saving design table, construction positioning general plan, doorman building plan, kindergarten basement plan, kindergarten plan, kindergarten elevation view, kindergarten section view, staircase details, bathroom details , Node detail drawings; water supply and drainage instructions, water supply and drainage construction drawings, construction instructions, water supply and drainage construction drawings, energy-saving design instructions, outdoor water supply and drainage general plans, outdoor water supply general plans, outdoor sewage general plans, outdoor rain general plans, water supply and drainage plans, spray Drainage plan, large-scale drawing of water supply and drainage in the pump room, schematic drawing of drainage system of the sump, large-scale drawing of water supply and drainage in the toilet, schematic drawing of water supply and drainage system, schematic drawing of rainwater system; structure description, basic floor plan, flat construction drawing, Structural floor plan, structural construction drawing, staircase construction drawing, node detail drawing, door guard structure construction drawing; electrical description, fire automatic alarm system construction drawing design description, public building construction drawing energy saving (green building) design description, weak electricity intelligent design description , Outdoor electrical general plan, room General plan of power consumption, general plan of outdoor weak current, detailed drawing of cable well, power cable laying section, automatic fire alarm system, automatic fire alarm plan, power distribution system, ground plan, electrical plan, lighting plan, lightning protection plan, Comprehensive wiring, computer network system diagram, Internet, equipment network, video surveillance system diagram, background music system diagram, perimeter prevention system diagram, multimedia teaching system diagram, multimedia conference system diagram, electronic patrol system diagram, computer room engineering system diagram, Weak current floor plan; ventilation design and construction instructions, kindergarten basement ventilation floor plan, toilet ventilation floor plan; landscape design description, plant design description, landscape greening general plan, green space area calculation plan, grid positioning general plan, size positioning general plan, vertical design General floor plan, general floor plan of paving, indexing, general floor plan of wall positioning, general floor plan of facility layout, detailed entrance floor plan, lighting selection plan, furniture selection plan, children's playground details, paddling pool details, flag raising platform Detail, ecological parking Drawings, detailed wall details, transparent wall details, general plans, greening plan, plant plan; decorative instructions, floor plan, top plan, floor plan, lamp positioning plan, hall elevation view, bathroom Elevation view, activity room, picture book room, sound room elevation view, node detail drawing, door table drawing, door node large sample drawing, etc. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation, landscape, decoration.
  • This project is a construction, structure, electrical, weak electricity, HVAC, water supply and drainage, and power construction drawing of a beverage factory relocation and expansion project. The land area is 200,000 square meters, and the total construction area is 234,426 square meters. This set of drawings contains: Main building with a building area of 83210 square meters, 3 floors above ground, 12 meters high; registration room, 4382 square meters, 1 floor above ground, 5.8 meters high; gatehouse and corridor, 244 square meters, 1 floor above ground, 3.3 meters high; Groundwater tank, pump room and boiler room, with a construction area of 780 square meters, a basement level of 6.5 meters high; ammonia press room, 632 square meters, two levels above the ground, 8.5 meters high; wastewater station, 1103 square meters, one level above the ground , 10.5 meters high; solid waste recycling station, 120 square meters, 1 floor above ground, 3.6 meters high; driver's lounge, 67 square meters, 1 floor above ground, 3.6 meters high; bicycle shed, 120 square meters, 1 floor above ground, high 2.2 meters; passenger car parking shed, 1173 square meters, 1 floor above ground, 2.2 meters high; pilot plant, 75,000 square meters, 6 floors above ground, 23 meters high; garage, 8600 square meters, 1 floor above ground, 8 meters high . The contents of the drawings include: architectural majors, building construction design instructions, building energy saving design instructions (main plant, registration room, gatehouse, driver's lounge), room tables (main plant, registration room, gatehouse & corridor, groundwater tank, Pump room & boiler room, ammonia compressor room, solid waste recycling station, driver's lounge, wastewater station), door and window tables, typical node details, general floor plan (first floor), general floor roof plan, vertical and Road map, traffic flow line schematic, fire flow line schematic, road & greening schematic, outdoor road detail, fence detail, trackless cantilever door detail, flagpole detail, building elevation profile, elevator, stair detail, ceiling , Floor, fire zone plan, bathroom detail plan, reclaimed water pump room, fire pump room and pool floor plan, production pool floor plan, stairwell section, etc. and structure, electrical, weak electricity, HVAC, water supply and drainage, power construction drawings And economic and technical indicator table, building energy saving calculation of office building part, registration room building energy saving calculation, doorman building energy saving calculation, driver lounge building energy saving calculation Calculation, calculation report of prescriptive index of public building, thermal performance judgment table of public building envelope structure, calculation of characteristic value of bearing capacity of composite foundation (cement-soil mixing pile), project overview and load calculation, ribbed foundation under wall Models and calculation books such as calculation, load calculation book, dead load, live load, structure, right wind, left wind diagram, corbel calculation, heat load calculation book, etc.
  • A full-scale professional construction drawing of a middle-to-high-level nursing home (including the feedback opinion sheet and calculation book), including nursing homes 1, 2 and a community health center. The seismic fortification intensity is 6 degrees, and the main structural form is the frame shear wall structure of the nursing home 1, the nursing home 2 and the community health center are frame structures. The nursing home 1 has a building height of 25.2 meters, 8 floors above the ground, and a building area of 7194.63 square meters (including insulation); the nursing home 2 has a building height of 18.8 meters, 6 floors above the ground, and a building area of 1426.31 square meters (counting The insulation height of the community health center is 13.3 meters, the number of above-ground floors is 3, and the building area is 2386.66 square meters (including the insulation layer). The contents of the drawings include: building instructions, energy-saving articles, floor plans, elevations, section views, large-scale drawings of staircases, enlarged plans of units, detailed drawings of nodes, enlarged views of kitchens and bathrooms, detailed drawings of walls, and enlarged views of facades of doors and windows; Water supply and drainage instructions, water supply and drainage, firefighting plan, sprinkler floor plan, water supply and hydrant system diagram, water supply and drainage system diagram, water supply and drainage system diagram, solar system schematic diagram, kitchen bathroom water supply and drainage detailed diagram, pump room system diagram; structure Description, plan layout of pile position, plan of foundation layout, layout of wall and column structure, detail of frame column, reinforcement, beam construction method, detail of node, detail of stairs; electrical description, fire alarm construction design instruction, System diagrams and legends, weak current construction design instructions and legends, low-voltage mains system diagrams, low-voltage power distribution system diagrams, detailed distribution room and strong power well diagrams, weak current system diagrams, distribution box system diagrams, power floor plans, lighting floor plans, roofs Lightning protection plan, foundation ground plan, fire alarm plan, weak current plan; HVAC instructions, indoor heating riser system diagram, heating level Figure, heating large drawing and so on. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • Multi-professional construction drawings for the excavation section of the southern section of a subway station. This project is a two-level underground structure, the first underground level is a property development layer, and the second underground level is a track area. At the southern end of the excavation section, the ground floor has a construction area of 1275 square meters. There are subway equipment management rooms on the 11 '~ 13' axis, including ventilator rooms, weak motor rooms, environmental control electrical control rooms, anti-hiding door control rooms, etc .; 1 ' The ~ 11 'axis is a property development, connected to the public area of the south hall of the subway station, and separated by fire-proof roller shutters. There are 2 entrances and exits on the ground floor of the open section in the southern section, which are connected to the ground. Entrance. The contents of the drawings include: architectural instructions, door and window selection tables, door and window selection instructions, general plan of the open section in the southern section, comprehensive decoration plans, floor decoration plans, ceiling decoration plans, wall positioning plans, detailed wastewater pump room practices, sections Diagram, black spraying schematic diagram of public area of property development, detailed drawing of maintenance manhole cover, large-scale drawing of drainage ditch maintenance cover, cable well plugging, skirting line, large-scale drawing of equipment drainage ditch, equipment area foundation, equipment area Large-scale drawings of railings, large-scale drawings of maintenance ladders, large-scale drawings of wall plugging of fire hydrant box holes, large-scale drawings of metal casing through wall plate hole plugging, detailed drawings of aluminum alloy ceilings, and details of short-type open air well protection covers , Metal and non-metal pipeline fire blocking installation drawing, metal air pipe through the floor hole fire block diagram, metal water pipe perforated fire block diagram, metal air pipe with insulation layer, metal water pipe with insulation layer fire floor block diagram , Metal air pipe through wall shrinkage hole fire blocking diagram, large-scale fire block diagram of power holes, anti-static raised floor anti-rat board layout, installation large-scale diagram, equipment area construction column, ring beam, doors and windows Detailed drawings of beams; water supply and drainage instructions, general floor plan for outdoor water supply and drainage, floor plan for sprinkler pipelines, floor plan for water supply and drainage, firefighting plans, floor plan for spraying, sectional views for water supply and drainage, firefighting systems, and water supply and production schematics , Water sprinkler system schematic diagram, large-scale drawing of waste water pump room, system diagram and material table, floor drain installation diagram, large-scale drawing of fire equipment box, outdoor pressure drainage well; power and lighting instructions, low-voltage switchgear arrangement diagram, electrical control Cabinet first and second load arrangement diagram, low-voltage cabinet floor plan, power distribution and grounding plan, lighting distribution plan, evacuation indication and guidance distribution plan, socket and indoor unit power distribution plan, escalator, weak current switch box system Figures, shop main box, shop sub-box system diagram, power distribution box system diagram, station maintenance power box, load switch box system diagram, lighting master box system diagram, emergency lighting cabinet system diagram, lighting circuit control schematic diagram; HVAC description , General plan, Ventilation and air conditioning plan, Ventilation and air conditioning system diagram, Fan installation diagram and so on. Specialties include construction, water supply and drainage, electrical, heating and ventilation.
  • Multi-professional construction drawings of a subway station, the seismic fortification intensity is 7 degrees, the total height of the station is 14.84 meters, the number of stations is 2 floors, and the total construction area is 11,662.48 square meters. The station is a two-story, three-span box structure, the first basement level is the station hall level, and the second basement level is the platform level; the effective platform width of the station is 12 meters, the standard section width of the station is 20.7 meters, and the width of the small-mile end shield shaft section is 24.6. The width of the shield section at the high-mileage end is 25.1 meters; the top of the station is covered with soil about 2 ~ 3.6 meters, and the excavation depth of the foundation pit is about 18.9 meters. There are 2 air ducts and 4 entrances and exits. The contents of the drawing include: architectural description, general plan of the station, main positioning coordinate diagram of the station hall floor, plan plan, longitudinal section, cross section, stairs, lower strand stairs, detailed drawings of the toilet, sewage pump room, large-scale drawing of the wastewater pump room, Large-scale drawing of drainage ditch retaining wall, fire hydrant in-wall installation, detailed drawing of maintenance manhole cover, maintenance ladder, cross-section ditch detailed drawing, anti-flooding protection closed partition door, large-scale drawing of civil defense partition door, shielding door end door Structural layout drawing, section view, hole plan view; water supply and drainage instructions, general outdoor water supply and drainage plan, water supply and drainage plan, station center section, fire water supply system diagram, production and living water system diagram, toilet water supply and drainage system Sample drawings, large-scale drawings of pump rooms, large-scale drawings of pools, sectional views of installation and installation of section pipelines, installation drawings of fixed brackets, detailed drawings of floor drain installation, detailed drawings of station flushing boxes, detailed drawings of fire equipment boxes, detailed outdoor pressure drainage wells Figure, Station civil air defense water supply design during wartime, detailed civil air defense schematic diagram, station civil air defense water supply schematic diagram (D-level chemical control), station civil air defense water supply and drainage block diagram (D-level chemical control), human Schematic diagram of anti-drainage drainage, plan view of personnel entrances and exits during wartime, large-scale drawing of the riser pipes of the rainwater pump room across the civil air defense roof, general diagram of water supply and drainage nodes in the basement of civil air defense; structural description, large-scale beam reinforcement and plane representation, station General plan of main structure, general plan of construction, structural floor plan, reinforcement plan, cross-section structure, general reinforcement structure, main and entrance interface diagram, main and wind pavilion interface diagram, main and shield interval interface diagram, enclosure General plan of the structure, plan of the foundation pit, plan of the supporting plan, elevation views of the left and right side retaining piles of the retaining structure, cross-section views of the retaining structure, diagrams of the retaining structure at the small and large mileage end walls, Station construction process diagram, steel support structure diagram, station foundation pit monitoring diagram; power and lighting instructions, civil air defense plan, civil air defense system diagram, socket power distribution plan, low-voltage main wiring diagram, switch cabinet energy management system diagram, smart meter settings Schematic diagram, switchgear system diagram, low-voltage switchgear plane layout diagram and quantity table, and intelligent low-voltage control system diagram for environmental control electric control cabinet; General description, general plan of station ventilation and air conditioning, schematic diagram of ventilation system, plan of ventilation and air conditioning, plan of ventilation system, plan of small system, schematic diagram of air conditioning water system, plan of station water system, layout of air curtain plane; comprehensive pipeline description, comprehensive pipeline Plan, section and more. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation, and integrated pipelines.
  • This project is a construction drawing and effect drawing of a kindergarten affiliated kindergarten in a central elementary school, including construction, structure, water supply and drainage, electrical, HVAC, landscape and interior decoration. The total land area is 3,624.14 square meters, and the area of the above-ground building (teaching room and gatekeeper and consumer control) 2466.86 square meters, excluding buildings (basement, outdoor fire pool, overhead activity venue) area of 431.63 square meters, children's playground (outdoor activity venue, overhead activity venue) area of 652 square meters, building floors, height: 1 floor above the guard , The building height is 3.8 meters, the fire height is 3.95 meters; 3 floors above the teaching building, 1 underground, the building height is 12 meters, the fire height is 12.175 meters; the outdoor pool, 1 underground; the building structure is a frame structure, and the seismic fortification intensity It is 6 degrees; the contents of the drawings include: architectural majors, general floor plans, general architectural design instructions, floor plans for the doorman, roof plans, elevations, section views, large node samples, large doors and windows for teaching rooms, energy-saving meters, basements And outdoor fire pools, first, second and third floors, roof plans, building elevations, section views, staircase details, Large samples of bathrooms, detailed drawings of joints; structural specialty, general description of structural design, construction plans of foundation beams, floor plan of first, second, third, roof floor structures, construction plans of wall columns, construction plans of column methods, construction plans of beam methods 、 Details of stairs, details of nodes, floor plan of door guard, floor plan of pool structure; HVAC specialty, ventilation design and construction instructions, basement ventilation floor plan, bathroom ventilation floor plan, first floor ventilation plan; electrical specialty, outdoor strong electricity design description, outdoor lighting Power distribution system diagram, cable well large-scale drawing, street lamp basic detailed drawing, outdoor strong electricity general floor plan, teaching room electrical design instruction, equipment material table, power distribution system drawing, vertical system drawing, basement electrical floor plan, basement grounding plan 、 Internal layout drawing of generator room, low-voltage power distribution system drawing of generator set, first, second and third floor electrical floor plans, roof lightning protection plan, foundation ground plan, automatic fire alarm design instruction, equipment material table, layout of interior control room, fire Automatic alarm system diagram, basement fire automatic alarm plan, fire door monitoring General plan, fire control equipment power monitoring system diagram, first, second and third floor fire automatic alarm floor plan, roof fire automatic alarm floor plan, outdoor weak current general floor plan, general description of intelligent system design, door guard first floor weak current floor plan, main equipment material table, Weak current system diagram, weak current floor plan, etc., as well as water supply and drainage specialty, interior decoration, landscape design and construction drawings, and overall effect drawings.
  • The contents of the drawings include: 120 samples of thick brickwork slabs, 240 samples of thick brickwork slabs, reference drawings of CAD wireboards, plans for outdoor fire pump rooms, sections, large samples of slab ladders, slab planes, and transformer chambers Large-scale sample, glass stainless steel pipe guardrail embedded parts, glass curtain wall fire-proof large-scale sample, lighting ventilation hood large-scale sample, side wall, ground waterproofing, large-scale waterproofing at the side wall of the platform, large-scale waterproofing of the gate fence and ground beam Samples, ground deformation joints, basement waterproofing, basement exhaust shaft large samples, basement construction joints, elevator large samples, elevator sump pit large samples, cinematic auditorium sight analysis diagrams, generator room exhaust heat samples, waterproof node large samples Sets, large samples of warehouses, steel ladders, large drawings of ancient building walls, water flooding out of pipes, schematic diagrams of pipeline penetrations, large samples of water traps, removable and buried water-proof deformation joints Drawings, detailed drawings of removable and embedded water-proof deformation joints, large-scale banisters, detailed railings, large-scale banisters, auditorium seating layout, auditorium sight design, facade clocks, beam ladders, floor ground deformation joints, buildings Surface deformation joints, floor and internal and external wall deformation joints Floor anti-seismic joints, large-scale roof staircase steps, open-ditch gutter cover starting point drainage ditch, daughter wall deformation joints, large-scale daughter wall large-scale, daughter-wall large-scale atlas, large-scale drainage ditch open-ditch cover, flat skylight details Drawings, large wall samples, large wall waterproof samples, wall column deformation joints, large-scale explosion-proof walls in civil air defense bases, large-scale drawings of commercial and residential buildings, large-scale drawings of upper and lower flat sizes, window sets, large-scale expansion joints Drawings, large-scale drawings of stone masonry corridors, outdoor granite steps, outdoor mosaic flower ponds, outdoor ramps, large-scale hydrophobic layers, cement mortar scattered water and water expansion joints, large-scale gutter daughter walls, iron ball cast iron rainwater outlets, Large sample of cornice panel, large sample of toilet and toilet, roof panel, large sample of gutter, large sample of roof panel, large sample of deformed roof, large sample of high and low span of roof, expansion joint of high and low span of roof, roof overhaul mouth.
  • There are many professional construction drawings for a subway station in a city. This station is a 4-layer underground excavation station with a 120-meter side platform. The total length of the station is 149.25 meters, the standard line spacing is 4.6 meters, the standard section width is 20.7 meters, and the total construction area is 7161 square meters. The effective length of the effective platform is 120 meters, and the total length of the shield door is 113 meters. There are 4 entrances and exits in the station, and the lengths of the entrances and exits are not more than 60 meters. The station adopts dual-end delivery and exhaust mode, with 7 groups of wind pavilions, a total of 11; the passenger flow situation of the station: the station's long-term design period is 2041, the long-term peak passenger flow is 35,500 people per hour, and the evening peak hour passenger flow is 32,809. Per hour, the over-peak coefficient is 1.31. The drawings include: power and lighting design instructions, civil air defense electrical design instructions, power distribution system diagrams, power distribution box system diagrams, power distribution floor plans, grounding plans, socket floor plans, lighting floor plans, power distribution box layouts, and low-voltage main wiring Figure, 400V switchgear intelligent low-voltage control system diagram, energy management system diagram, smart meter setup diagram, follow the low-voltage switchgear system diagram, low-voltage switchgear plan layout and quantity table, lighting distribution plan for public areas of the station hall, advertising and Evacuation instruction power distribution plan, guide power distribution plan, station A and B emergency lighting power supply system diagram, intelligent lighting control network diagram, environmental control electrical control cabinet first and second load system diagram; water supply and drainage instructions, outdoor water supply and drainage General floor plan, water supply and drainage, fire floor plan, sectional view, air conditioner room drainage plan, floor plan, fire hydrant system, production and domestic water supply system, main wastewater pump room large-scale detailed drawing, local wastewater pump room large-scale detailed drawing and main Material table, section fire floor plan and system diagram, section pipe layout and installation section view, section pipe fixed bracket installation Figure, floor drain installation schematic diagram of the station hall and platform, floor drain installation detail in the public hall of the station hall, detailed drawing of the station flushing box, detailed drawing of the fire equipment box, detailed drawing of the outdoor pressure drainage well; decoration design description, door and window selection description, general Floor plan, decoration floor plan, general plan of equipment room renovation, black-out schematic plan view, cross-sectional view, axis station floor wall positioning plan, waste water pump room detail view, maintenance manhole cover details, drainage ditch maintenance cover, cable well seal Large-scale diagrams of plugging and skirting; ventilation and air conditioning description, general plan of station ventilation and air conditioning, schematic diagram of tunnel ventilation system, schematic diagram of station large system, floor plan of mezzanine tunnel ventilation system, floor plan of tunnel ventilation system platform, floor plan of equipment of tunnel ventilation system , Plan of jet fan in the tunnel ventilation system, floor plan of the station hall system, air-conditioning room plan, small system schematic, small system plan, equipment management room air-conditioning system renovation, station air-conditioning water system plan, section view, main equipment layout Plan view; comprehensive pipeline description, comprehensive pipeline plan, cross-section view Wait. Specialties include power lighting, water supply and drainage, decoration, HVAC, and integrated pipelines.
  • Civil hydropower garden model and construction drawing of a model demonstration area, plant part: planting instructions, checklist, general plan of plant configuration, zone index map, tree, shrub and ground cover configuration plan. Hydropower: landscape engineering irrigation, rainwater, drainage, lighting design. Including: water and electricity description, water and drainage plan, lighting, electrical, power system diagram, water and electricity installation details, garden plan lighting layout sideline diagram, Yongquan, villa entrance, mountain water view plan, main entrance water view left, right side plan Illustration. Civil works include: garden construction instructions, general details and model areas, floor plans of parking lots, materials, vertical, index, parts plan views, dimensions, grid line plans and main entrance plans and details, materials, structural plans Arrangement plan, gate plan view, main entrance steel structure plan, materials of the second door area and extension section, index, vertical, line drawing plan, elevation section view, large water view, detailed view of Erdao Mountain Gate, and mountain-shaped water view plane Arrangement plan, elevation and positioning plan, detailed cross-section sample and sales department passage, pay-off plan, step pay-out enlarged plan and detail, steel structure plan, standard section of solid wall railing, waterscape Tingbu flower pond large sample, sale Large-scale roof terrace and villa front yard, laying plan, back yard materials, index, vertical, laying plan, gallery, plan view and detail of the plank road, entrance water feature, door, fence, stone flower Bowl, water curtain, water feature, wrought iron railing, grille, detailed retaining wall detailing, vertical index of large flat floor, laying, material floor plan and small wall, stone bench, detailed view of landscape wall. Contains SKP models and renderings
  • The new construction project of a county people's hospital, a psychiatric hospital, has a base area of 5450.0 square meters and a total construction area of 19936.9 square meters, of which the ground level is 19413.9 square meters and the underground is 523 square meters. There are 336 beds, including 294 in psychiatry and 42 in general. There are six floors above ground and one underground, with a height of 23.7m. The structural form is a reinforced concrete frame structure. Design scope: general floor plan, fire and greening general plan, building description, energy-saving chapter, green building chapter, vertical section view, bathroom details, floor elevator details, wall prototypes, node details, doors and windows Table and large sample and structure description, pile position plan, floor beam cap layout, cap detail, foundation ground beam, wall, slab, column plan, wall, column reinforcement, structure plan, Beam reinforcement diagram, stair plan layout, stair detail and water supply and drainage instructions, water supply and drainage, fire hydrant, automatic sprinkler floor plan, cold water main pipe system schematic diagram, hot water system schematic diagram, water supply, fire hydrant, automatic sprinkler system principle Drawings, large-scale drawings of water supply and drainage for firefighting and domestic pumping houses, electrical instructions, power distribution, lighting, roof lightning protection, grounding plan, substation high-distribution line diagram, vertical power distribution system, low-voltage power distribution system Figures, equipment layout of transformer substations, indirect layout of transformer substations, low-voltage distribution energy consumption monitoring system diagrams and HVAC instructions, main equipment material tables and installation details, smoke exhaust ventilation Plane, air-conditioning refrigerant pipes and condensate pipe plane, FIG smoke control system, multi-air conditioning system of FIG.
  • The project includes two parts, a comprehensive building and a canteen, all of which are three types of buildings. Contains the vertical section and node details of the architectural specialty; the professional construction drawings and node details of the curtain wall; the basic and main construction drawings of the structural specialty; the design of mains, lighting, electricity, evacuation, air conditioning, fire protection, lightning protection and grounding for the electrical specialty; Professional gas pipeline layout; heating and ventilation professional office buildings and cafeteria heating, changing rooms, bathrooms, distribution rooms and kitchen ventilation, air conditioning in the main rooms of office buildings and canteens, smoke exhaust on the second and third floor of office buildings; Drainage professional domestic water supply system; domestic drainage system; hot water system; rainwater system; hydrant water supply system; automatic sprinkler water supply system; fire extinguisher configuration and so on.
  • The project is a construction project of Fujian Vanke Plaza, including 1 # super high-rise comprehensive building, 2 # high-rise comprehensive building (divided into 2 # A, 2 # B, 2 # C), 5 # multi-storey commercial building, and architectural floors The numbers are 33, 13, 17, 13, 2 and the basement are 2 floors. The building heights are 166.2, 66.9, 89.15, 66.9, and 8.8 meters, and the building areas are about 58194.42, 16918.32, 5126.75, 22172.78, and 948.91 square meters. Meter. The drawings include construction and energy-saving design instructions, general floor plans, first floor and vertical design, comprehensive general floor plans for fire protection, landscaping, and pipelines, vertical sectional views, equipment, structural conversion floor plans, core tube details, bathroom details, and walls Detailed drawings, detail drawings of nodes, enlarged views of curtain wall facades, large-scale drawings of doors and windows; structural water supply and drainage HVAC electrical drawings, etc. (missing 5 # building structure HVAC drawings).
  • This project is a construction project of a national fitness activity center in a county in Ningxia, including a gymnasium and a stadium. The building layers are 1, 3, building heights are 28.95, 42.667 meters, and building areas are 20514.34 (among which, the underground building area is 3,293.38 square M), 12961.21 square meters, the structural forms are frame spherical grid steel structure, frame steel grid structure, the design service life is 50 years. The drawings include architectural design instructions, energy-saving design articles, general floor plans, vertical sectional views, fire-proof zoning plans, large-scale drawings of stairs, bathrooms, large-scale drawings of stands, site layout plans, large-scale drawings of walls, and detailed drawings of doors and windows; Structural design instructions, foundation construction drawings, beam, slab, column construction drawings, steel structure grid construction drawings; water supply and drainage professional, HVAC professional, electrical professional drawings.
  • This project is the overall landscape design project of the Beijing Courtyard Villa District, including garden construction, structure, plants, water supply and drainage, electrical, real pictures, SKP model, PDF version of the overall landscape design plan. The drawings include architectural design instructions, entrance dimensions, coordinate plan views, entrance door elevation sectional views, detailed drawings, entrance garage entrance details, water view details on both sides of the entrance, entrance view wall views, drop water details, streams Detailed drawing, detailed drawing of wall, detailed drawing of children's activity square; structural design description, structure drawing of main entrance and secondary entrance door, structural drawing of water view of spectacle wall, structural drawing of water view on both sides of the entrance; design description of water supply and drainage, floor plan of water supply and drainage , System diagram; electrical design description, electrical general floor plan, power distribution system diagram; planting design description, planting general floor plan, real-world photos and so on. (With sales center SKP model, PDF version of the overall landscape design plan).
  • A future city B plot 4 #, 5 #, 7 #, 8 # residential building projects are all 20 floors above the ground, the building area is about 87.00 square meters, the building height is 61.2m, the drawings contain architectural design instructions, energy-saving design Special chapter, floor plan, elevation sectional view, detailed drawings of stairs, walls, large-scale samples, etc .; 5 # building pile plan, floor plan, foundation details, wall column, beam and plate construction drawing , Top waistline and masonry drawings of each floor; water supply and drainage, firefighting plan, water supply and drainage system schematic diagram, hydrant system diagram, water supply and drainage plan, point map; HVAC design instructions, floor heating plan, kitchen Ventilation floor plan, roof floor positive pressure air supply floor plan, heating riser system drawing, pressurized air supply system drawing, etc .; distribution trunk system diagram, weak current system diagram, fire house automatic alarm system diagram, distribution box system diagram, floor plan, Electricity, lighting, weak current, automatic fire alarm floor plan of each floor, etc.
  • The project is a land project in Beijing, including 1 # ~ 4 # building, 1 # building is a self-occupied commercial residential building, the number of building floors is 8 floors, and the above-ground building area is 12704.04 square meters; 2 # 4 # building is ordinary Commercial housing, of which there are 2 floors in a courtyard, 3 floors in a row, 6 floors stacked, and the floor area is 2606.981 square meters. The 3 # building is an ordinary commercial housing with 3 floors and a building area of 1020 square meters. The drawings include architectural design instructions, vertical section views, large-scale plan plans, detailed stairs plans, large-scale wall plans, and large-scale drawings of doors and windows; structural design instructions, ground plan of the ground floor, two-story walls, hidden columns, and top beams, Floor layout of each floor structure and reinforcement plan, staircase detail, dark column detail; HVAC design instructions, heating and ventilation plan, heating riser plan, and tube well detail (missing 2 # ~ 4 # professional water supply and drainage electrical drawings) .
  • A hotel project in Jilin Province with 6 floors above ground and 1 underground floor with a total construction area of 46451.19㎡ and a building height of 24m; the structural form is a frame structure, and the drawings include: architectural design instructions, floor plans for each floor, schematic diagrams of fire protection zones, elevation sections, and axes Enlarged detailed drawings, detailed drawings of the core of the staircase elevator, detailed drawings of the ramp, etc .; Structural design instructions, flat construction drawings of each floor beam plate, column wall layout drawings, construction drawings of the basement roof beam roof structure, floor reinforcement design; water supply and drainage design instructions , Floor plan of water supply and drainage of each floor, floor plan of shower, large-scale drawing of bathroom, water supply and drainage system, rain system, fire hydrant, sprinkler system, etc .; HVAC design instructions, HVAC schematic diagram, underground floor ventilation plan , Floor plan of air-conditioning wind and air-conditioning water system on each floor, floor plan of geothermal coil, large-scale drawing of tube well and system drawing, etc .; construction drawings of electrical and steel structures, etc.
  • Merger of commercial office villa models in a park. The total land area is about 130,000 square meters, and the construction area is about 430,000 square meters. Contains high-rise, multi-story, low-rise buildings.
  • Full-scale professional construction drawing of 202 # workshop of a certain innovation demonstration park, base area: 6936.63 square meters, building area: 55864.63 square meters, fire height: 38 meters, planned height: 38.55 meters, 8 floors above ground, 6 meters above ground, 2 ~ 8 The height of each layer is 4.5 meters, and the structural form is a frame shear wall structure. Contents include building level, elevation, section, location, stairs, bathroom details, wall details, door and window tables and details, decoration practice table, engineering practice table, building description and structure description, foundation construction drawing, column plan Layout drawing, shear wall construction method, beam floor construction method, floor plan construction drawing, staircase detail drawing and water supply and drainage instructions, floor water supply and drainage pipe plan, bathroom water supply and drainage pipe plan enlarged view, domestic water supply and drainage system diagram 、 Hydrant water supply pipe and automatic spraying water supply pipe system diagram and strong and weak electricity description, distribution box system diagram, lighting, electricity plan, lightning protection plan, basic grounding plan, weak electricity system diagram, fire protection, weak electricity plan and HVAC instructions, equipment Table, air-conditioning ventilation plan, air-conditioning water pipe riser system diagram, new fan unit, fan coil pipe takeover details.
  • This project is a construction project of an exhibition hall in Jiangsu. The building has 3 floors, 1 underground, a building height of 12.35 meters, and a building area of 1965.08 square meters, of which the underground building area is 643.52 square meters. The structural form is a frame structure. It is designed for use. The period is 50 years. The drawings include architectural design instructions, green design special articles, vertical section views, staircase details, bathroom details, curtain wall large-scale drawings, wall details, doors and windows details; structural design instructions, basic floor plan, column plan Reinforcement diagrams, beam plane reinforcement diagrams, structural plan diagrams, staircase details; water supply and drainage design instructions, water supply and drainage floor plans, toilet water supply and drainage large-scale drawings, system diagrams; HVAC design instructions, air conditioning and ventilation, water pipe plans; electrical design instructions, Electricity, lighting, firefighting, weak current floor plans, system diagrams (including curtain wall drawings, etc.).
  • The project is a construction project of a Wanda City hotel in Jiangsu, which includes four-star hotel A, four-star hotel B, and six-star hotel C. The number of building floors is 8, 9, and 3, and the ground floor is 1 and the building heights are 45.7. , 47.63, 23.95 meters, the building area is 42561.66, 45259.6, 49152.89 square meters, the structure forms are frame shear, frame, frame structure. The drawings include architectural design instructions, fire special chapters, green special chapters, general floor plans, plan elevation sections, schematic diagrams of fire protection zones, large-scale elevation drawings, guest room areas along the lake, courtyard elevations, various guest room details, boiler rooms , Living pool, fire fighting pool, high and low voltage substation, refrigeration heat exchange machine room plan details, stairs, bathroom, linen room, walls, doors and windows details; structural professional, water supply and drainage professional, HVAC professional, electrical professional drawings (Missing drawings for hotel B stairs).
  • This project is a construction project of a commercial square in Ningxia. The building has 15 floors, one underground, a building height of 59.6 meters, a building area of 14,546 square meters, a structural form of a frame structure, and a design life of 50 years. The drawings include architectural descriptions, vertical sectional views, floor and elevator details, bathroom details, doors and windows details; structural descriptions, shear wall, column plan views, edge member node diagrams, beam and plate reinforcement diagrams, and staircase details; Water supply and drainage instructions, water supply and drainage, firefighting, sprinkler floor plans, private rooms, apartment water supply and drainage large-scale drawings, water supply and drainage, fire hydrants, sprinkler system diagrams; HVAC instructions, heating, heating mains, ventilation smoke exhaust plan, system diagrams; Electrical description, main line, lighting, weak current and fire door monitoring, automatic fire alarm, lightning protection and ground plan, system diagram.
  • Full professional construction drawings (including calculation books) of a high-rise residential building, including a basement. The seismic fortification intensity is 6 degrees for residential buildings and 7 degrees for basements. The main structural form is a frame shear wall structure; the residential building has a height of 98.7 meters, 32 floors above the ground, and a total construction area of 10929.8 square meters; the basement has 1 floor. The buried depth is 5.45 meters, and the building area is 50232.32 square meters. The contents of the drawings include: architectural description, general plan, floor plan, elevation, sectional view, core tube stairs, elevator details, porch details, large-scale wall drawings, assembly railing details, node large-scale drawings, window guardrails Detailed drawings, detailed roof drawings, large sample drawings of construction methods, detailed drawings of kitchen and bathroom, large samples of ramps, wind wells, large samples of nodes, large samples of doors and windows, schematic drawings of basement roofs; water supply and drainage instructions, water supply system drawings, fire hydrants System diagram, drainage system diagram, water supply and drainage and firefighting floor plan, water supply pipeline detailed drawing, apartment water supply and drainage pipeline system detailed drawing, basement sprinkler layout plan; structural description, reinforced concrete beam reinforcement flat representation, stair construction general diagram and Description, pile foundation plan, floor structure plan, reinforcement diagram, shear wall plan, flat construction drawing, large-scale sample and pile table of rotary excavation cast-in-situ pile, roof layout plan, detailed stairs, large-scale drawing, roof Detailed drawings; electrical instructions, residential interior decoration electrical design instructions, residential interior decoration legends and descriptions, distribution trunk plan, lighting plan, weak current embedded pipes Floor plan, automatic fire alarm plan, lightning protection and grounding plan, household distribution box wiring diagram, electrical location plan, decoration lighting plan, decoration socket plan, decoration weak current plan; HVAC instructions, pressurized air supply system diagram, ventilation Floor plans and more. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • In a residential area, there are 13 residential buildings, 1 community sports building, 5 transformer rooms and basement projects. The 1 ~ 10 # building is 27 floors above ground, 1 basement, building height 79.90, 79.95m, construction area 12420.37 ~ 17789.69㎡, 11 ~ 13 # building is 8 floors above the residential floor, building height is 24.9m, building area is 4321.6㎡, 14 # building is 2 floors above community sports building, building height is 11.6m, building area is 309.35㎡, substation The houses are all 1 floor above ground, 1 basement floor, building height of 6.6m, and construction area of 302.1 ~ 798.34㎡; the drawings include: architectural design instructions, engineering practice tables, general floor plans, underground garage roof plans, underground floor plans, and underground floors Schematic diagram of fire protection zone, building energy saving design, green building design, floor plan, elevation sectional view, stairwell and elevator zoom, floor plan, large door, large wall, doors and windows and doors and windows Figures; general description of structural design, plan of pile position, plan of foundation, plan of wall column, plan of wall column, construction plan of beam and plate, detail of stairs and ramps, detail of nodes
  • 1 ~ 4 # building projects in a residential area are all 2 floors underground, 31 floors above 1 #, building area of 36504.36㎡, building height of 99.9m, 26 floors above 2 # building, building area of 23446.93㎡, building height of 84.2 m, 3 # building 35 floors above ground, building area of 40494.73㎡, building height of 119m, 4 # building 19 floors above ground, building area of 8387.59㎡, building height of 62.7m, drawings include: architectural design instructions, catalogue, unified building construction practices Table, general floor plan, floor plan, elevation section view, elevator room floor plan, roof plan, floor plan enlarged, stair detail, large node drawing, door and window table and door and window detail; structural design description, pile floor layout Drawing, foundation plan, structure plan, wall column construction drawing, large-scale sample table of shear wall column, beam reinforcement plan, staircase structure diagram; water supply and drainage design description, hydrant system partition diagram, water supply and drainage plan, large sample , System diagram, fire hydrant system schematic diagram; electrical design instructions, distribution box system diagram, low voltage vertical power distribution system diagram, automatic fire alarm and linkage control system diagram, fire leakage Alarm system diagram, floor, socket, lighting, firefighting floor plan; HVAC design instructions, main equipment material table, underground floor ventilation and smoke exhaust floor plan, underground floor heating pipeline plan, floor heating and heating trunk plan, pressurization Air supply plan, air-conditioning air and air-conditioning pipeline plan, positive pressure air supply system diagram, heating riser and condensate riser system diagram, large-scale drawing of plumbing well
  • This project is a professional construction drawing and effect drawing of an 18 # residential building for construction, structure, electrical, HVAC, water supply and drainage. The total construction area is 4411.57 square meters, 6 floors above ground, 1 underground, 17.95 meters high, frame-shear structure; drawings Contents: Architectural specialty, special measures for residential engineering, architectural design instructions, building energy-saving design, green building design, general floor plan, unit large-scale plan, building floor plan, elevation view, section view, detailed stairs , Wall samples, door and window tables, door and window details, bicycle entrance and exit details; structural specialty, structural design instructions, basic structure drawings, wall and column construction drawings, beam flat construction drawings, plate flat construction drawings, stair details, Detailed node drawings, large wall samples; electrical majors, electrical design instructions, legends, material tables for major equipment, green building design articles, weak current system diagrams, power distribution system diagrams, lighting and socket floor plans, weak current floor plans, basement floor grounding, and Trunk plan, roof lightning protection plan; HVAC specialty, HVAC design and construction instructions, heating plan, main equipment material table, heating system diagram, Detailed drawing of heating practices; water supply and drainage majors, water supply and drainage design and construction instructions, green building design special articles, main equipment tables, drainage system diagrams, water supply system diagrams, condensate system diagrams, pipeline well details, solar water heater schematic diagrams, unit units Sample plan, water supply and drainage plan.
  • This project is a professional construction drawing of multiple residential buildings in a residential area, including structure, structure, electrical, HVAC, and water supply and drainage. Among them, 1 #, 8 #, 11 #, 12 #, 17 #, 18 #, 21 #, 22 # Building, 8 floors above ground, 2 underground floors, 24.3 meters high, total construction area is 6889.99, 10088, 10192.13, 10032.23, 10204.94, 10138.53, 10513.35, 7498.35 square meters, shear wall structure; 2 #, 6 #, 9 # , 10 #, 15 #, 16 #, 19 #, 20 #, 23 # building, 12 floors above ground, 2 underground floors, 36.3 meters high, the total construction area is 7494.44, 12079.91, 12069.26, 8159.29, 8104.19, 8043.09, 8052.06 , 7957.69, 779.91 square meters, shear wall structure; 3 #, 5 # building, 18 floors above ground, 2 underground floors, 53.4 meters high, total construction area is 16358.2, 11015.99 square meters, shear wall structure; 7 # building , With a total construction area of 5912.54 square meters, 7 floors above ground, 2 underground floors, a height of 24.1 meters, a shear wall structure; an underground garage with a total construction area of 3,5259.6 square meters, one underground floor. The contents of the drawings include: architectural majors, general architectural design instructions, building energy-saving design tables, construction practice tables, sets of indicators tables, interior decoration practice tables, general floor plan, floor plans, building elevations, section views, and stair details Drawings, enlarged floor plans of units on each floor, wall joints, windows and doors, large windows and doors, floor plans for each floor; structural specialty, general description of structural design, pile layout, foundation plan, foundation beam construction method, shear wall method Construction drawings, reinforcement members for shear wall structures, reinforcement detail tables, node details, beam flat construction drawings, floor structure plans, terrace steel structure gallery plans, large scale stairs, wall nodes, structure plan reserved hole layout plans ; HVAC specialty, general description of HVAC design, main equipment and equipment tables, legends, heating system diagrams, detailed drawings, floor plans of the second floor heating mains, ventilation, floor plans of the first floor, floor plans of floor heating; water supply and drainage majors, water supply General description of drainage design, schematic diagram of water supply and drainage system, schematic diagram of rainwater and condensate system, schematic diagram of hydrant system, main design Equipment table, water supply and drainage floor plan, standard floor type water supply and drainage detailed drawing, system diagram, bathroom underground water supply and drainage detailed drawing, drainage system drawing, pressure drainage system detailed drawing; electrical major, general description of electrical design, power distribution, weak electricity vertical Directional system diagram, bill of materials, electrical system diagram, power distribution, lighting, weak current plan, roof lightning protection plan, foundation ground plan, etc.
  • Full-scale professional construction drawings (including energy saving design review filing form, energy saving design report, and heat load calculation report) of multiple high-rise residential buildings in a community, including 17 ~ 19 # building. The seismic fortification intensity is 7 degrees. The main structural forms are shear wall and frame structure. The building height is 97.4 meters (from the outdoor ground to the top of the daughter wall). The number of above-ground layers is 33 and the number of underground layers is 2. The construction area is 15163.1, 15159, 14989.34 square meters. The contents of the drawings include: building description, green building design, building energy saving design, floor plan, elevation, section, large unit drawing, stairs, elevator details, bicycle ramp details, wall details, Detailed drawings of shafts, detailed drawings of doors and windows; water supply and drainage instructions, solar water heating system design instructions, water supply and drainage and hydrant floor plans, machine room floor water supply and drainage plans, water supply system drawings, hydrant system drawings, sewage system drawings, rainwater system drawings, condensate water systems Drawings, large-scale water supply, large-scale drainage drawings, large-scale water supply and drainage pits, large-scale drawings of pipe wells; structural description, general description of civil air defense structure design, assembly structure design description, pile plan layout, foundation Floor plan, staircase detail, bicycle ramp detail, hidden column detail, flat construction drawing, typical node drawing, horizontal component layout drawing, stair installation layout drawing, large-scale plan of laminated board, stair component detail drawing; electrical Description, diagram of power distribution, diagram of power distribution system, diagram of weak current system, description of automatic fire alarm, diagram of fire protection system, large-scale drawing of electric well, floor plan of lighting, distribution level Map, lightning protection plan, grounding plan, weak current plan, firefighting plan, positioning plan; HVAC instructions, green building design, detailed drawings of plumbing pipes, heating and ventilation plans, floor heating coil plans, heating system drawings, heating pipe details Figures and more. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • Fully professional construction drawings (no general floor plan) of multiple high-rise residential buildings in a community, including 9 ~ 10, 13 ~ 14, 16 ~ 17, 21 ~ 22 # buildings. The seismic fortification intensity is 7 degrees, and the main structural form is a shear wall structure. Among them, 10, 14, 17, 21, and 22 # are all 17 above-ground floors, 1 are underground, the building heights are 52.2 meters, and the building area is 88.95797 to 13,294.726 square meters; 9, 13, 16 # The number of above-ground floors is 18, the number of underground floors is 2. The building height is 55.05 meters and the building area is 10959.59 ~ 11923.034 square meters. The contents of the drawings include: building description, green building special chapter, floor plan, elevation view, section view, unit plan detailed drawing, staircase large-scale drawing, wall detail drawing; water supply and drainage instruction, green building design special article, water supply and drainage, fire protection Floor plan, water supply system diagram, drainage system diagram, large-scale air conditioning condensate water diagram, fire hydrant system diagram, sump drainage system diagram; structural description, pile plan layout, reinforcement diagram, flat construction diagram, reinforcement table, distribution Reinforcement plan, structural plan, large-scale diagram of staircase structure; electrical description, low-voltage power distribution system trunk line diagram, low-voltage power distribution system diagram, weak current system diagram, fire alarm description and legend, fire system diagram, lighting plan, emergency lighting plan, electrical Trunk plan, socket plan, weak current plan, fire alarm plan, roof lightning protection plan, foundation ground plan; HVAC instructions, HVAC plan, heating system diagram, large-scale pipe drawing, large-scale thermal inlet diagram, positive pressure feed in front room Wind system diagram, integrated pipeline plan, etc. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • The project is a professional construction drawing of a central city for architecture, structure, electrical, HVAC, water supply and drainage. The total planned land area is 181,717 square meters, and the planned total construction area is 492858.03 (492583.14) square meters. The building height and the number of floors are: (commercial part ) 1 # building, 2 floors above ground, 11.9 meters high; 8 # building, 2 floors above ground, 11.9 meters high; 13, 14 # building, 2 floors above ground, 1 basement floor, 11.9 meters high; 15 # building, 3 floors above ground , 1 floor underground, 17.8 meters high; 16, 17 # building, 1 floor above ground, 11.9 meters high; 22, 23 # building, 1 floor above ground, 6 meters high; 27 # building, 1 floor above ground, 6 meters high; 32 #Building, 2 floors above ground, 11.9 meters high; 39 # Building, 2 floors above ground, 11.9 meters high; 42 # Building, 2 floors above ground, 11.9 meters high; Gatehouse, 1 floor above ground, 4.8 meters high; 7 # kindergarten, 3 floors above ground, 12.75 meters high; (residential part) 5, 6, 34, 36 # residential buildings, 11 floors above ground, 1 underground, 32.9 meters high; 11, 24, 40, 47 # residential buildings, 28 floors above ground, 1 basement floor, 84.15 meters high; 18, 19, 20, 43, 44, 45 # residential buildings, 33 floors above ground, 1 basement floor, 99.15 meters high; 21, 41, 46 # buildings, 30 floors above ground, 1 basement floor , 90.15 meters high; 25 # building, ground 27 floors, 1 underground, 81.15 meters high; drawings include: architectural majors, general floor plans, roads and vertical layouts, schematic diagrams of fire passages and ascending rescue surfaces, architectural design and construction instructions, building energy-saving design, green building design instructions , Architectural vertical section, large samples of doors and windows, large samples of nodes, large samples of stairs, large-scale design of basement and construction instructions, engineering practice table, statistical table of doors and windows, basement floor plan, fire partition and safety evacuation schematic diagram, basement roof plan, sectional view , Large-scale drawing of car entrance and exit ramp, Large-scale drawing of nodes, Large-scale drawing of stairs, Large-scale drawing of non-motor vehicle ramp, Large-scale drawing of power distribution room, Building energy-saving design report; Structural specialty, General description of basement structure design, Basement Basic floor plan, basement column floor plan, basement roof floor plan, basement roof reinforcement plan, basement frame beam flat construction drawing, basement secondary beam flat construction drawing, automotive ramp structure detail, non-motor vehicle ramp structure Detailed drawings, large-scale drawings of stairs, etc. , Water supply and drainage, HVAC professional construction drawings.
  • Fully professional construction drawings of multiple high-rise residential buildings in a community (including review reply sheet), including 1 ~ 8 # residential building, commercial S1 floor and basement. The seismic fortification intensity is 8 degrees. The main structural forms are divided into residential buildings and basement shear wall structures. The commercial S1 floor is a frame structure. Among them, the number of floors above the commercial S1 floor is 1 layer, the building height is 13.5 meters, and the building area is 1444.38 square meters; the number of floors above the 6 and 7 # buildings is 16 layers, the number of underground floors is 2 layers, and the building heights are 50 meters, the construction area is 9827.76, 8517.78 square meters; 3, 5, and 8 # are all 17 floors above ground, 2 underground floors, 50.3 meters building height, and building area of 8717.44 ~ 13056.1 square meters Meters; 1, 2, 4 # are 20 floors above ground and 2 floors underground, building height is 50.3 ~ 59 meters, building area is 8012.57 ~ 8012.57 square meters; basement is 1 underground, building The area is 25,543.89 square meters. The contents of the drawings include: building instructions, building design fire prevention chapter, green building design chapter, building energy saving design chapter, general plan positioning plan, floor plan, elevation view, section view, large-scale sample plan, floor elevator detail drawing, door Head detail, window well detail, wall detail; water supply and drainage instructions, drainage and firefighting plan, roof drainage plan, spray plan, water supply system diagram, hydrant system diagram, drainage system diagram, rainwater system diagram, sprinkler system Schematic diagram, large-scale plan of apartment water supply and drainage system, large-scale plan of apartment water supply and drainage system, large-scale image, large-scale drawing of fire water tank, schematic and detailed diagram of solar water heating; structure description, basic floor plan, wall column plan , Raft reinforcement plan, pile plan, floor plan, reinforcement plan, template plan, staircase detail, wall detail, ramp detail, secondary air defense entrance and exit detail, door frame wall detail, post-cast belt layout Figures, detailed drawings of frame columns and retaining walls; electrical instructions, seismic, energy-saving, and green building design instructions, strong electrical vertical trunk system diagrams, power distribution system diagrams, weak electricity system diagrams, automatic fire alarm system diagrams, electricity Detailed construction drawings, lighting plans, strong and weak mains power distribution plans, power distribution plans, fire alarm plans, weak current plans, roof lightning protection plans, foundation ground plans, electrical layout plans; HVAC instructions, green building design , Ventilation floor plan, Heating floor plan, Schematic diagram of pressurized air supply, smoke exhaust, heating system, large-scale drawing of heating and ventilation practices; decoration instructions, original floor plan, wall plan, floor plan, floor layout plan, ceiling layout plan, ceiling Dimensional drawings, lamp positioning maps, switch wiring diagrams, socket layout diagrams, elevation index diagrams, halls, overall sandbox area, negotiation area, bathroom access, planning department, reading bar, signing room / finance room, children's entertainment area, water Bar, reference room, conference room, general office, manager room, general office, property department, men's and women's façade, node diagram, etc. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation, and decoration.
  • Full-scale professional construction drawings of multiple high-rise residential buildings in a certain district (including the response to the review opinion), including 1 ~ 5 # residential buildings (4 # buildings are community supporting houses), S01 # community supporting houses and underground garages. The seismic fortification intensity is 7 degrees, and the main structural forms are divided into residential building shear walls and frame structures, community supporting houses are frame structures, and underground garages are slab-column seismic walls. Among them, the number of floors above and below the building # 1 are 32, the number of floors is 3 and 2, the building heights are 95.19, 96.6 meters (outdoor ground to the top of the daughter's wall), and the building areas are 34148.46, 16499.83 square meters. Meters; 2 ~ 4 # buildings have 6 floors above ground, 2 # 3 buildings have 3 underground floors, 4 # buildings have no underground floors, building height is 19.89-20 meters, and building area is 3261.26-16499.83 square meters ; S01 # Community supporting premises has 1 floor, building height is 5.1 meters, building area is 324.1 square meters; underground garage is 2 floors, building area is 16,652.02 square meters. The contents of the drawings include: building instructions, civil air defense engineering design instructions, green building design special articles, building energy saving design special articles, underground wartime floor plans, floor plans, elevations, section views, unit large-scale drawings, large-scale stairs, elevators Large-scale drawings, large-scale drawings of wall nodes, detailed drawings of civil defense, detailed drawings of doors and windows, large-scale drawings of car ramps, wartime and usual civil defense plans of underground garages; water supply and drainage instructions, water supply and drainage, firefighting plans, firefighting system diagrams, spraying Draining schematic diagram, drainage tank drainage, civil air defense water tank system diagram, water tank floor plan, water supply and drainage large-scale diagram, water supply system diagram, indoor cold and hot water system diagram, pipe well large-scale diagram, drainage system diagram, spraying Floor plan; structural description, civil air defense structure design description, special instructions for precast concrete laminated slabs, pile layout plan, foundation raft layout plan, detailed details of foundation members, reinforcement diagrams, flat construction drawings, structural floor construction drawings, roof floor trellis layout Plan, plan layout of horizontal member structure, component drawing, detailed drawing of stair reinforcement, construction drawing of professional leaving hole for plumbing, detailed drawing of foundation component, hidden column table; electrical Lighting, energy saving and seismic design instructions, civil air defense electrical design instructions, automatic fire alarm system design instructions, civil air defense system drawings, lighting floor plans, power floor plans, fire floor plans, foundation ground plans, electric well layouts, automatic fire alarm system drawings, Distribution main line diagram, weak current system diagram, emergency lighting system diagram, power distribution system diagram, electrical floor plan, electrical trunk plan, prefabricated roof electrical point positioning plan, top positioning plan, wall positioning plan, socket plan, weak current plan, Roof lightning protection plan; HVAC instructions, green building design, civil air defense design instructions and machine room plans, ventilation plans, heating plans, heating plans, large-scale drawings of plumbing wells, pressurized air supply schematics, heating and heating systems Figures and more. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • A professional construction drawing of a high-rise commercial and residential building with an earthquake fortification intensity of 7 degrees, the main structural form is a shear wall structure, the building height is 99.9 meters, the number of above-ground floors is 32, the number of underground floors is 1, and the total construction area is 25918.33 Square meters. The contents of the drawings include: architectural instructions, energy-saving design, floor plans, elevations, section views, large-scale plan plans, node details, large-scale stair plans, elevator large-scale plans, car ramp plans, and water well sections. Figures, large-scale drawings of doors and windows, large-scale drawings of commercial bathrooms; water supply and drainage instructions, water-and-drainage plans, spraying plans, large-scale drawings of water collection wells, gas fire extinguishing system diagrams, water-and-drainage system diagrams, apartment-type water-and-drainage diagrams, commercial toilets Large-scale drawing of water supply and drainage, Large-scale drawing of water supply and drainage pipelines in pump room, System drawing of water supply and drainage pipelines in pump room; Structure description, Pile foundation structure description, Pile position plan layout, Frame column structure plan layout, Flat construction drawing, Basic floor plan, large foundation drawing, detailed edge component drawing, reinforcement drawing, car ramp node large drawing, node large drawing, stair large drawing, frame column table; electrical instructions, energy saving design for public buildings, lighting Floor plan, electrical floor plan, weak current floor plan, grounding floor plan, fire floor plan, lightning protection plan, floor plan of equalizing ring with ten or more floors, basement trunk line Electrical floor plan, unit vertical power supply, power distribution system diagram, commercial phone, broadband wiring system diagram, pump room power wiring diagram, unit video intercom, cable TV system diagram, unit phone, broadband wiring system diagram, automatic fire alarm system ; HVAC instructions, ventilation and smoke exhaust plan, positive pressure air supply system diagram, and so on. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • Multi-professional construction drawings of a number of high-rise residential buildings, including 1-27 # building, kindergarten and basement. The seismic fortification intensity is 6 degrees, and the main structural form is a shear wall structure. Among them, 1-3, 6-10, 12, 14, 15, 18-21, 24-27 # The floors above the floor are all 18 floors, and the building height is 53.85-53.9 meters; 4, 5, 11, 13, 16 , 17, 22, 23 # The number of floors above the ground is 26, the building height is 77.25-78.6 meters, the number of floors above the kindergarten is 4, the building height is 16.35 meters, and the building area is 4584.08 square meters; the planned total building area is 232794.96 square meters. The contents of the drawing include: water supply and drainage instructions, green building construction drawing water supply and drainage design instructions, outdoor water supply and drainage node large-scale drawings, outdoor water supply and drainage general floor plans, outdoor water supply and drainage general floor area plans, water supply and drainage and fire floor plans, automatic sprinkler floor plans, Standard floor water supply and drainage and fire floor plan, roof floor water supply and drainage and fire floor plan, large-scale apartment water supply and drainage plan, water supply and drainage system diagram, fire hydrant system deployment schematic diagram, water supply system deployment schematic diagram, sewage and wastewater system deployment schematic diagram, self-spraying system Expand the schematic diagram, the large-scale drawing of the bathroom water supply and drainage; structure description, pile foundation structure design description, foundation pile position layout plan, foundation structure floor plan, column floor plan, structure floor plan, reinforcement plan, motor vehicle ramp Large-scale drawings, plan views of pile positions, plan views of pile caps (rafts), layout plans of wall columns, construction drawings of beam flat method, detailed drawings of staircases, general large-scale drawings; electrical instructions, special green building design articles, weak current system diagrams, Automatic fire alarm system diagram, vertical power distribution system diagram, distribution box system diagram, electrical large-scale diagram, lighting floor plan, socket movement Floor plan, lighting power plan, weak current fire floor plan, roof lightning protection plan, foundation ground plan; HVAC instructions, air conditioning and ventilation construction drawing design instructions and green special (HVAC) design instructions, air conditioning and ventilation engineering installation instructions, ventilation and smoke prevention Floor plan, pressurized air supply system, etc. Specialties include structure, water supply and drainage, electrical, heating and ventilation.
  • The construction drawing of a high-rise residential building, the seismic fortification intensity is 7 degrees, the main structural form is a shear wall structure, the foundation type is a raft foundation, the building height is 77.35 meters, the number of above-ground floors is 26, and the number of underground floors is 2. The base area is 520.76 square meters, and the total construction area is 12,755.23 square meters, of which the total construction area above ground is 11,685.42 square meters, and the total underground construction area is 1069.81 square meters. The number of residential houses in this building is 104. The contents of the drawings include: building description, green building design, general plan positioning plan, plan view, elevation view, section view, comprehensive enlarged plan of the house, comprehensive drawing of the cave, enlarged view of the elevator, detailed drawing of the ramp, and detailed drawing of the node , Large-scale drawings of doors and windows, doors and windows table, engineering practices table.
  • This project is a professional construction drawing of a residential building No. 1 (units A, B, C, and D) and office buildings, kindergarten buildings, structures, electrical, HVAC, and drainage. Among them, the total building area of Building 1 is 31,386.33 square meters. Meters, building height of 60 meters, building layers are: 13, 18, 20, 20 floors, a total of 230 households; office building building layers are 3 underground floors, 15 floors above ground; kindergarten building floors are 3 floors above ground ; The contents of the drawing include: No. 1 residential building construction major, architectural design instructions, underground mezzanine floor plan, fire zone schematic diagram, first floor plan, second floor plan, third to thirteenth floor plan, fourteenth floor plan, fifteen to eighteenth floor Floor plan, floor plan of the 19th and 20th floors, floor plan of the machine room floor, roof floor plan, building elevation, section view, hall plan, elevation view, section view, doors and windows table, door and window elevation enlarged view, kitchen and bathroom detailed drawings; office Building structure specialty (lack of structural design instructions), floor reinforcement plan, beam reinforcement floor plan, roof, machine room floor reinforcement, beam reinforcement floor plan, underground sandwich plate reinforcement floor plan, negative three floors to negative one floor Shear wall layout plan, edge component detail plan, shear wall layout plan for each floor, edge component detail plan, machine room floor shear wall layout plan, edge component detail plan, shear wall reinforcement table, stair table, stair detail ; Electrical major, design and construction instructions for strong electricity in office buildings, legends and main equipment material tables, vertical system trunk diagrams, electrical fire monitoring system diagrams, power distribution system diagrams, lighting distribution system diagrams, kindergarten strong electricity design and construction Description, legend and main equipment material table, kindergarten vertical system main line diagram, electrical fire monitoring system diagram, power distribution system diagram, weak electricity floor plan of machine room floor of building 1, weak electricity floor plan of roof layer, weak electricity floor plan of underground mezzanine and above ground; HVAC Professional (lack of HVAC design instructions), main equipment and material tables, smoke prevention system schematic diagrams, heating system diagrams, underground mezzanine ventilation machine room details, plumbing pipe well details, machine room floors, roof floor heating and ventilation floor plans, underground mezzanine and Floor plan for heating and ventilation above ground; water supply and drainage specialty (lack of water supply and drainage design instructions), floor plan for underground mezzanine spray, water supply Drainage and hydrant floor plan, ground floor sprinkler floor plan, water supply and drainage and fire hydrant floor plan, engine room floor water supply and drainage and hydrant floor plan, roof floor equipment floor plan, water supply and drainage system development plan, fire protection system development plan, sprinkler system development plan, standard floor heating Media floor plan, heat medium system diagram.
  • A future city B plot 4 #, 5 #, 7 #, 8 # residential building projects are all 20 floors above the ground, the building area is about 87.00 square meters, the building height is 61.2m, the drawings contain architectural design instructions, energy-saving design Special chapter, floor plan, elevation sectional view, detailed drawings of stairs, walls, large-scale samples, etc .; 5 # building pile plan, floor plan, foundation details, wall column, beam and plate construction drawing , Top waistline and masonry drawings of each floor; water supply and drainage, firefighting plan, water supply and drainage system schematic diagram, hydrant system diagram, water supply and drainage plan, point map; HVAC design instructions, floor heating plan, kitchen Ventilation floor plan, roof floor positive pressure air supply floor plan, heating riser system drawing, pressurized air supply system drawing, etc .; distribution trunk system diagram, weak current system diagram, fire house automatic alarm system diagram, distribution box system diagram, floor plan, Electricity, lighting, weak current, automatic fire alarm floor plan of each floor, etc.
  • The project is a land project in Beijing, including 1 # ~ 4 # building, 1 # building is a self-occupied commercial residential building, the number of building floors is 8 floors, and the above-ground building area is 12704.04 square meters; 2 # 4 # building is ordinary Commercial housing, of which there are 2 floors in a courtyard, 3 floors in a row, 6 floors stacked, and the floor area is 2606.981 square meters. The 3 # building is an ordinary commercial housing with 3 floors and a building area of 1020 square meters. The drawings include architectural design instructions, vertical section views, large-scale plan plans, detailed stairs plans, large-scale wall plans, and large-scale drawings of doors and windows; structural design instructions, ground plan of the ground floor, two-story walls, hidden columns, and top beams, Floor layout of each floor structure and reinforcement plan, staircase detail, dark column detail; HVAC design instructions, heating and ventilation plan, heating riser plan, and tube well detail (missing 2 # ~ 4 # professional water supply and drainage electrical drawings) .
  • This project is a professional construction drawing of a 39 # villa building, structure, electrical, HVAC, water supply and drainage, with a total construction area of 474.13 square meters, 3 floors above ground, and a height of 12.35 meters; the contents of the drawings include: architectural specialty, general instructions for the design of construction drawings 、 Indoor and outdoor decoration construction method table, first floor plan, second floor, third floor, roof plan, building elevation, section view, wall sample, kitchen and bathroom sample, stair sample, general sample, door and window Large-scale drawings, windows and doors tables, large-scale drawings of balustrade facades; professional structure, general structural design instructions, basic floor plans, basic cross-section size tables, large samples connecting the foundation and the beam, the top of the foundation ~ one-story floor column construction method Plan, one-story floor to two-story floor column flat construction drawing, two-story floor to three-story floor column flat construction drawing, three-story floor to roof column flat construction drawing, first floor, second floor, Three-story, roof structure plane layout and slab reinforcement diagram, beam flat construction drawing, wall sample, stair reinforcement diagram, stair construction general diagram and description, reinforced concrete beam reinforcement plane representation explanation; electrical specialty, electrical construction General design instructions, legends and Material table of main equipment, system diagram of distribution box, large-scale drawings of building lightning protection contacts, first floor, second floor, third floor electrical floor plan, first floor, second floor, third floor, lightning protection ground plan, roof lightning protection plan; warm General, ventilation and air conditioning design and construction general instructions, equipment list, first, second, and third floor air-conditioning floor plans; water supply and drainage professional, indoor water supply and drainage construction drawing design general instructions, water supply pipe system details, drainage pipe system details, first Floor, second and third floor water supply and firefighting floor plans, first floor, second and third floor drainage floor plans, etc., as well as air conditioning configuration tables, structural foundation calculation books, stairs calculation books, etc.
  • A professional construction drawing of a low-rise villa with an earthquake fortification intensity of 7 degrees. The main structural form is a frame structure with a building height of 9.15 meters, two floors above the ground, and a total construction area of 329.88 square meters. The contents of the drawings include: architectural instructions, floor plans, elevations, section views, detailed stairs, door and window details, node details, door and window tables; water supply and drainage instructions, water supply and drainage system drawings, water supply surface details, and drainage plan details; Structural description, basic floor plan, frame-column reinforcement plan, beam reinforcement plan, structural floor plan and plate reinforcement plan, staircase details; electrical description, power distribution system diagram, socket plan, lighting plan, weak current plan, foundation Ground plan, roof lightning protection plan; HVAC instructions, heating and ventilation plan. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • A villa residential area project, including villa 1 # 3 floors above ground, 1 underground, building area of 767.32㎡, building height of 13.9m; 2 # building 3 floors above ground, 1 underground, building area of 666.97㎡, building height Is 13.69m; three-row row 1 #, 2 #, 6 # 3 floors above ground, 1 underground, building area is 1373.95㎡, building height 14.44m; four-row row 5 # three floors above ground, 1 underground, building The area is 1751.15㎡ and the building height is 14.44m. The six-row row 3 # and 4 # are 3 floors above ground and 1 basement, the building area is 2528.71㎡, the building height is 14.44m, 7 # ~ 10 # are 3 floors above ground and underground 2 floors with a building area of 2666.02㎡ and a building height of 14.44m; Shuangpin 1 # ~ 5 # 3 floors above ground and 1 basement floor with a building area of 1173.17㎡ and a building height of 13.9m; drawings include: architectural design instructions, Material practice table, vertical sectional view, door and window table and door and window detail drawing, staircase and toilet detail drawing, node detail drawing; structural design description, foundation plan layout drawing, column plan layout drawing, beam and plate construction method drawing, stair structure reinforcement drawing; Water supply and drainage design instructions, water supply and drainage trunk plan, water supply and drainage plan, system ; HVAC design instructions, heating mains plan, heating plan, system diagram; electrical design instructions and legends, main and ground plans, lighting, sockets, low-voltage pipeline reserve plans, roof lightning protection plans, power distribution system diagrams , Weak current system diagram
  • Architectural floor plan, elevation view, section view, staircase, bathroom detail drawing, node detail drawing, door and window statistical table, door and window form division drawing, basic floor plan, foundation detail drawing, column reinforcement diagram, beam reinforcement diagram, and plate assembly Reinforcement drawings, large samples of bathroom pipes, water supply and drainage system drawings, water supply and drainage floor plans, power distribution system drawings, strong current plans, ground plans, weak current plans
  • This project is a multi-professional construction drawing of a relocation housing project. The number of building floors: 2 floors above the ground, a building height of 7.05 meters, a total building area of 829.79 square meters, a structural system of masonry structure, and a design life of 50 years. The drawing includes architectural design instructions, floor plans, elevations, section views, detailed drawings of each floor; structural design instructions, basic floor plans, floor plans of each floor structure, detailed drawings; water supply and drainage design instructions, floor plans and system drawings of each floor; HVAC design description, floor heating plan, system diagram; electrical design description, lighting, electricity, weak current floor plan, lightning protection plan, system diagram, etc.
  • This project is a professional construction drawing of a villa building, structure, electrical, HVAC, water supply and drainage. The total construction area is 506.91 square meters, the number of building floors is 2 floors above ground, and the structural form is a frame structure. It contains: general description of architectural design, General description of structural design, electrical design description, material practice table, building vertical sectional view, node large sample drawing, staircase sectional view, floor plan, bathroom large sample, door and window statistics table, door and window detailed drawing, basic floor plan, column reinforcement Diagram, column top reinforcement, beam reinforcement, stair reinforcement, roof reinforcement, ground beam reinforcement, roof top beam reinforcement, structural node details, power supply system, weak current system, Electrophotographic floor plan, weak current floor plan, ground plan, water supply and drainage design instructions, water supply and drainage plan, water supply and drainage system drawings, hot water system drawings, HVAC design instructions, heating trunk plan, heating system drawings, heating floor plans.
  • This unit is a three-story new rural single-family house with a brick-concrete structure, a total construction area of 379.92 square meters, an area of 159.30 square meters, and a cornice building height of 10.10 meters, including architectural, structural, water supply and drainage, and electrical drawings.
  • Construction drawing of a villa, with a total construction area of 253.88 square meters, a height of 9.3 meters, and a three-story brick-concrete structure; the contents include: architectural design instructions, structural design general instructions, water supply and drainage and electrical design instructions, building elevation section views, and staircase details Drawings, wall nodes, doors and windows table, engineering practice table, foundation plan, node detail drawing, structural plan construction drawing, electrical, water supply and drainage professional drawings
  • The project is a self-built villa construction project in Sichuan. The building has 3 floors, a building height of 10.5 meters, a building area of 518.9 square meters, a structural form of a frame structure, and a design life of 50 years. The drawings include architectural instructions, vertical sectional views, staircase details, kitchen and bathroom details, node details, door and window tables; structural descriptions, foundation plan, column plan method, beam plan method, structural plan, and stair details .
  • Multi-professional construction drawings of a super high-rise office building (including project introduction and picture album), the seismic fortification intensity is 7 degrees, the tower is a "dense column frame-core tube" lateral force system, and the upper floor system is a composite floor supported by steel beam System; the basement (except the tower) side-resistance system uses a frame system, the basement floor system is a beam-slab system. The building height is 392.5 meters, the number of above-ground floors is 66, and the number of underground floors is 4. The total construction area is 265040.72 square meters, and the total land area is 15,658.41 square meters. The contents of the drawings include: building description, energy-saving design description, general description of civil air defense design, green building description, axis positioning plan, floor plan, elevation view, landscape greening schematic diagram, awning details, wall node details, civil defense mouth And stairs, floor elevators, escalators, ramp details, wind wells, node details, core tube, bathroom plan, basement machine room, glass sheet steel bridge, VIP Enlarged view of the drop-off area; water supply and drainage instructions, civil air defense and drainage design instructions, external storage pressure heptafluoropropane gas fire extinguishing system design instructions, prefabricated heptafluoropropane gas fire extinguishing system design instructions, outdoor water supply and drainage general plan, domestic water supply and water system schematic diagrams, Sewage and wastewater drainage system schematic diagram, fire hydrant system schematic diagram, automatic sprinkler system schematic diagram, domestic drainage system schematic diagram, water supply and drainage and fire fighting floor plan, automatic sprinkler combination floor plan, civil air defense water supply and drainage system diagram, underground water supply and drainage during wartime Floor plan, gas fire floor plan, toilet water supply and drainage plan, pump room water supply and drainage large-scale drawing; Construction description, civil air defense engineering structure design description, tower structure positioning plan, wall column positioning plan, core tube shear wall section steel positioning plan, pile foundation description and large-scale drawing, pile foundation plan, floor plan, structure plan Figure, Reinforcement diagram, Core tube shear wall section, Column foot joint detail, Ground steel beam embedded parts detail, Cap detail, Wall column positioning plan, Structural template plan, Office supporting structure plan, Art gallery Entrance hall structure plan, large-scale civil air defense entrance and exit, large-scale civil air defense wall and water collecting well, four underground underground civil defense wall pillars, holes in the floor, detailed elevator floor plan, large-scale basement side wall, large-scale fire-fighting pool, driveway plan; Description, 10kV high-voltage power supply system schematic diagram, 10kV high-voltage power distribution system primary wiring diagram, 10kV high-voltage substation equipment layout, ground plan, 10kV high-voltage substation wiring layout, 10kV high-voltage substation cross-section view, distribution trunk System diagram, power distribution system diagram, equipment layout plan, wiring layout diagram, section view, lighting plan, power plan, distribution box system diagram, power supply system diagram, Ray described grounding system and large drawing, a schematic diagram of a ground system, lightning protection system schematic plan view of a ground mine like. Majors include architecture, structure, water supply and drainage, and electrical.
  • The project is a professional construction drawing of the first phase of a square office building # 1, office building, structure, electrical, HVAC, water supply and drainage. The construction area on the ground is 29779.8 square meters, 10 floors above ground, 2 underground floors, 36.6 meters high, frame structure; drawings Contents: Architectural specialty (lack of architectural design instructions), architectural plan, elevation, section, wall detail, and staircase details; structural specialty, general description of structural design, general description of reinforcement design, -0.11m, 4.16 m, 8.16m elevation plate transformation diagram, elevation beam transformation diagram, 11.66m, 15.16m, 18.66m, 22.16m, 25.66m, 29.16m, 32.66m, 36.2m elevation plate reinforcement diagram, elevation beam reinforcement diagram, Negative two-story, negative one-story column layout, one, two, three to six, seven to eight, nine, ten-story column layout, column table, wall detail, stair detail; electrical major, electrical design instructions , Green building electrical energy-saving design special instructions, electrical system diagrams, power distribution plans, lighting plans, roof lightning protection plans, fire plans; HVAC majors, HVAC design and construction instructions, side air conditioning unit installation large-scale drawings, the next output Installation of air-conditioning units Sample drawing, large-scale drawing of installation of lower air-conditioning air-conditioning unit, smoke prevention, fire valve function table, main air-conditioning ventilation legend, air-conditioning water system diagram, air-conditioning water level plan, equipment and schedule, smoke exhaust system diagram, pressurized air supply system Map, air-conditioning ventilation, smoke prevention and exhaust plan; water supply and drainage professional (lack of water and drainage design instructions), water supply system diagram, sewage drainage system diagram, sprinkler schematic diagram, sprinkler plan, rainwater drainage diagram, condensate system diagram, fire hydrant System diagram, large-scale drawing of toilet water supply, large-scale drawing of toilet drainage, large-scale drawing of plumbing well, design instruction of sevoflurane automatic fire extinguishing system, and water supply and drainage plan.
  • This project is a professional construction drawing of a building, structure, electrical, HVAC, water supply and drainage. The total construction area is 1720.64 square meters, 4 floors above ground, 16 meters high, frame structure; the contents of the drawings include: architectural specialty, architectural design instructions, Engineering practice table, building energy-saving design instructions, door and window tables, first, second, third, and fourth floor plans, roof plans, building elevations, section views, large-scale drawings of staircases, large-scale samples of walls; structural specialty, general description of structural design , Grey soil compaction pile layout plan, foundation floor layout plan, foundation detail drawing, one to two, three, and four-story column plane reinforcement diagrams, ground beam layer beam plane reinforcement diagram, one, two to three, and four layer beam planes Reinforcement diagram, one, two to three-layer board plane reinforcement diagram, staircase plan, detailed staircase; electrical major, general description of electrical design, material table, power distribution system diagram, general equipotential bonding plan, roof lightning protection plan, First, second, third, and fourth floor lighting plans, outlet plans, emergency lighting plans, weak current plans; HVAC specialty, HVAC design instructions, first floor heating trunk ventilation plan, first floor heating plan, Floor plans for heating, ventilation, and heating systems on the second, third, and fourth floors; water supply and drainage majors; water supply and drainage design and construction instructions; floor plans for water supply and drainage on the first, second, third, and fourth floors; water supply system drawings; drainage system drawings; toilet water supply and drainage arrangements Figure, hydrant system diagram.
  • Multi-professional construction drawings (including project list and project electrical inventory form) of a three-phase and one-phase project of a cloud data center, including data room, comprehensive building and fire tank. The seismic fortification intensity is 7 degrees for category B, and seismic measures are adopted according to 8 degrees for category B. The main structural forms are divided into a data room, a comprehensive building with a steel frame structure, and a fire-fighting pool with a cast-in-place reinforced concrete frame structure. Among them, the building height of the data room is 13.2 meters, the number of floors above the ground is 1,200, and the total building area is 23,200 square meters. The building height of the comprehensive building is 6.95-20.8 meters, the number of floors above the ground is 1, and the total building area is 1,655 square meters. The building height is 4.6 meters, the number of above-ground floors is 1 and the number of underground floors is 1. The total construction area is 736 square meters. The contents of the drawing include: general plan, vertical layout, road plan, green layout, earthwork balance, cable routing location map, transmission pipeline location map, building description, floor plan, elevation view, section view, detailed stairs, toilet Detailed drawings, large-scale wall drawings, detailed node drawings; water supply and drainage instructions, gas fire extinguishing system design and installation instructions, fire water supply and drainage construction drawings, fire hydrant system drawings, water supply and drainage, fire protection, fire hydrant floor plans, large bathroom drawings, high level Fire fighting water tank system schematic diagram, gas fire extinguishing system action control flow chart, rainwater and condensate drainage system diagram, toilet water supply and drainage large-scale drawing, gas fire extinguishing startup pipeline connection diagram, sprinkler system schematic diagram, water sprinkler layout plan, gas Layout plan of fire extinguishing system; structural description, layout of foundation plane, steel column, steel beam, horizontal brace, self-supporting floor slab layout and reinforcement diagram, purlin structure layout diagram, staircase detail standard section diagram, node detail diagram, Standard node diagram, wall structure layout diagram; electrical description, fire automatic alarm system design description, distribution Box system diagram, power trunk diagram, distribution box system diagram, power distribution, electrical, socket, emergency lighting, lighting, grounding, roof lightning protection floor plan, fire alarm system and floor plan, fire alarm control, electrical fire monitoring and very early Fire alarm system plan, fire alarm plan, gas fire extinguishing and linkage control plan, very early alarm plan, large-scale layout of TV wall; HVAC description, air-conditioning system schematic, air-conditioning system end schematic, machine room smoke exhaust schematic, exhaust Smoke system plan, heating plan, equipment floor plan, air-conditioning duct plan, smoke exhaust plan, ventilation plan, air-conditioning water plan, refrigerant tube, humidification tube, condensate tube plan, data machine room cross-sectional view, three-dimensional schematic diagram; decorative design instructions, Ground pavement map, integrated ceiling picture on the top, flat roof detail on the bathroom, node detail on the bathroom sink, step node detail on the liquid-cooled machine room, fire blocking on empty wall holes, fire blocking node on cable tray through wall holes ; Process description, schematic layout of the closed hot aisle, cable routing diagram, FIG first cabinet configuration system, locations, and sizes of holes through the wall schematic layout FIG cabinet, shelf power traces floorplan schematic arrangement grounding system, the bus is a schematic and small system like FIG. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation, decoration, and technology.
  • Fully professional construction drawing of a multi-story office building, the seismic fortification intensity is 8 degrees, the main structural form is a frame shear wall structure, the building height is 23.1 meters (including 1.5 meters indoor and outdoor height difference), the number of above-ground floors is 5, and the underground The number is 1 floor, with a total construction area of 8,467.58 square meters, of which the floor area is 6,934.70 square meters, and the underground construction area is 1,532.88 square meters. The contents of the drawings include: architectural instructions, green building design, floor plans, elevations, section views, large-scale drawings of stairs, large-scale drawings of walls, large-scale drawings of car ramps; water supply and drainage instructions, floor plans of water supply and drainage hydrant pipes, Floor plan of engine room, floor plan of fire pump room, sprinkler plan, water supply and drainage piping system, spray principle diagram, hydrant piping system diagram, fire pump room piping system diagram, pipe well riser layout; structural description, basic layout Floor plan, wall and column floor plan, reinforcement plan, staircase detail plan, canopy floor plan, canopy steel beam, short column plan, canopy rigid frame, steel column, support layout, canopy purlin layout Figures, details of canopy rigid frames, details of canopy nodes; electrical instructions, power distribution system diagrams, weak current system diagrams, distribution main plan, lighting plan, socket plan, weak current main plan, automatic fire alarm plan, public lighting plan , Roof lightning protection plan, foundation ground plan; HVAC instructions, green building design, ventilation plan, smoke exhaust schematic, etc. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • This project is a 2 # building construction project of a residential area in Bowen, Gansu, Gansu Province, with a total construction area of 462.703㎡, a building height of 18.35m (outdoor design ground to the top of the daughter wall), four floors above the ground (partial five floors), and a multi-layer public structure Building, the first floor is a shop, the second to fourth floors are offices, and the fifth floor is a roof staircase and tool room. The drawings include: design instructions, catalogs, main equipment tables, power distribution system diagrams, and distribution box system diagrams. Emergency lighting system diagram, weak current system diagram, fire control room power distribution system diagram, ground floor plan, roof lightning protection plan, power and lighting floor plans, weak floor plans
  • Structure drawing, architectural drawing, general drawing and tower crane layout drawing of Yuekang Phase III Pharmaceutical Factory. Yuekang Pharmaceutical Science, Industry and Trade Industrial Base Project-Multi-purpose plot. The nature of the building: multi-purpose plots for offices, medical research and underground parking garages. Main structural form: The building adopts frame shear wall structure, and the foundation adopts raft foundation. Includes electrical construction drawings for buildings, structures, and distribution rooms
  • Vanke? Crowded Garden. Including vertical section and node detail drawings of construction majors; structural professional foundation and main construction drawings; ventilation and central air conditioning design of buildings for heating and ventilation majors; domestic water supply and drainage systems for drainage and drainage, basement wastewater systems, indoor and outdoor hydrant water supply System, sprinkler water supply system, gas fire extinguishing system, mobile fire extinguishing device.
  • The project is a construction project of Fujian Vanke Plaza, including 1 # super high-rise comprehensive building, 2 # high-rise comprehensive building (divided into 2 # A, 2 # B, 2 # C), 5 # multi-storey commercial building, and architectural floors The numbers are 33, 13, 17, 13, 2 and the basement are 2 floors. The building heights are 166.2, 66.9, 89.15, 66.9, and 8.8 meters, and the building areas are about 58194.42, 16918.32, 5126.75, 22172.78, and 948.91 square meters. Meter. The drawings include construction and energy-saving design instructions, general floor plans, first floor and vertical design, comprehensive general floor plans for fire protection, landscaping, and pipelines, vertical sectional views, equipment, structural conversion floor plans, core tube details, bathroom details, and walls Detailed drawings, detail drawings of nodes, enlarged views of curtain wall facades, large-scale drawings of doors and windows; structural water supply and drainage HVAC electrical drawings, etc. (missing 5 # building structure HVAC drawings).
  • This project is a commercial office complex construction project in Hubei, including A1 #, A2 # commercial, A3 # office, B1 # office, the number of floors is 3, 3, 28, 16 and the height is 14.75, 13.95, 115.75, 65.15 meters , The area is 1548.52, 2437.74, 41737.68, 22948.33 square meters, and the designed service life is 50 years. Drawings include architectural instructions, general floor plans, upright sectional views, detailed drawings of stairs, elevators, escalators, toilets, walls, nodes, doors and windows; structural descriptions, wall pillars, beams, formwork and plate reinforcement, detailed stairs; Drainage instructions, floor plan, water supply and drainage, self-spraying, fire hydrant system diagram; HVAC description, ventilation and air conditioning, smoke exhaust, air conditioning water pipe plan, system diagram; electrical description, strong electricity, weak electricity, fire protection, electricity, lightning protection grounding plan, System diagram.
  • A full-scale professional construction drawing of a low-rise farmer's market, the seismic fortification intensity is 7 degrees, the main structural form is a frame structure, the building height is 12.15 meters, the number of above-ground floors is 1, the number of underground floors is 1, and the total construction area is 5347.18 square meters. The contents of the drawings include: architectural description, general plan, plan, elevation, section, enlarged plan of stairs, large-scale drawings of doors and windows; water supply and drainage instructions, plans, fire pump room and fire pool piping, self-spraying plans, large-scale bathroom Diagrams and system diagrams, water supply and drainage system diagrams; structural description, basic floor plan, reinforcement plan, flat construction drawing, structural floor plan, grid positioning diagram; electrical description, box-type substation system diagram, vertical Power distribution trunk map, power distribution box system diagram, power well layout sample map, fire control room layout sample map, grounding plan, power plan, roof lightning protection plan, lighting plan, automatic alarm and fire linkage control system diagram, video Monitoring system diagram, comprehensive wiring system diagram, elevator operation control system diagram, fire alarm plan, weak current plan; HVAC instructions, air-conditioning ventilation plan, ventilation plan. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • A professional construction drawing of a low-rise vegetable market, the seismic fortification intensity is 7 degrees, the main structural form is a frame structure, the building height is 11.3 meters, the number of floors above the ground is 2, and the total building area is 3792.58 square meters. The contents of the drawings include: building instructions, energy saving articles, fire prevention articles, door and window details, green building design instructions (public buildings), floor plans, elevations, section views, stair details, escalator details, bathroom details , Node detail drawings; water supply and drainage instructions, water supply and drainage and firefighting plans, roof rainwater drainage plans, shower plans, large-scale bathroom plans, water supply and drainage system diagrams; structure description, basic floor plan, column positioning and reinforcement diagrams, foundation Reinforced beam drawing, plate and beam reinforcement drawing, wall detail drawing, roof shape detail drawing, staircase structure drawing; electrical description, low voltage power distribution system drawing, power floor plan, lighting floor plan, fire floor plan, roof lightning protection plan , Basic grounding plan; HVAC instructions, heating ventilation plan, floor radiant heating plan, etc. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • Fully professional construction drawing of a low-rise sales office, the seismic fortification intensity is 7 degrees, the main structural form is a steel frame structure, the building height is 10 meters, the number of floors above the ground is 2, the building area of the first floor is 974.3 square meters, and the building area of the second floor It is 1045.4 square meters, with a total construction area of 2019.7 square meters. The contents of the drawings include: architectural instructions, wall holes, floor plans, elevations, cross-sections, large staircase drawings, enlarged bathroom plans, large elevator drawings, large wall drawings, enlarged details, door and window details; Drainage instructions, water supply and drainage system diagrams and bathroom details, water supply and drainage plans; steel structure design instructions, foundation plans, steel structure foot plans, structural plans, reinforcement plan, steel structure node details, stair structure details; electrical description , Power trunk and fire alarm system diagram, low-voltage distribution box (cabinet) system diagram, power plan, foundation ground plan, roof lightning protection plan, lighting socket plan, fire alarm and weak current plan; HVAC instructions, air-conditioning ventilation plan, air-conditioning Refrigerant system floor plan and more. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • This project is the construction drawing of Chengdu China Hydropower Fanyue International South District. It consists of high-rise tower No. 1 with 4 floors of podiums, No. 2, No. 3, No. 4 commercial buildings and No. 2 basement. The drawings include professional construction drawings of buildings, structures, water supply and drainage, HVAC, and electrical (1 # 楼 6 ~ 21st floor beam reinforcement plan, roof floor beam reinforcement plan is incomplete, 2 # electrical lacks lightning protection).
  • The project is a commerce and logistics park project in Ningxia, including 4 factories and commercial buildings, and 4 comprehensive buildings. The number of factory buildings and commercial buildings are 2 floors, with a building area of 11489.2, 8641.25, 8886.69 square meters; the comprehensive building has 11 floors, and the building area is 20024.31, 21705.77, 24606.94, 21717.2 square meters. Drawings include architectural design instructions, vertical sectional views, detailed drawings of stairs, walls, doors and windows; structural design instructions, basic floor plans, wall columns, beams, slab reinforcement diagrams, detailed stairs drawings; steel structure design instructions, column foot anchors , Structure, crane beam layout, roof, wall purlin layout, detailed staircase; water supply and drainage design instructions, water supply and drainage, fire hydrant, sprinkler floor plan, system diagram; HVAC design instructions, heating and ventilation plan, system diagram; electrical Design description, lighting, weak current, fire automatic alarm plan, system diagram.
  • The project is a four-storey catering business center in Xi'an, Shaanxi. The building area is 19,623.87 square meters. The building structure is a steel frame structure. The building structure safety system is Grade II. The seismic fortification intensity is 7 degrees. The drawing includes architectural design instructions, floor plans, elevations, section views, and detailed drawings of each floor; structural design instructions, foundation floor plan, floor beam and plate reinforcement drawings at each floor, column bolt layout, and node details; Drainage design description, floor water supply and drainage plan, spray floor plan, water supply and drainage system diagram, hydrant, self-spraying system diagram; HVAC design description, air-conditioning air plan of each floor, air-level water plan of each floor, system diagram, etc.
  • The project includes two parts, a comprehensive building and a canteen, all of which are three types of buildings. Contains the vertical section and node details of the architectural specialty; the professional construction drawings and node details of the curtain wall; the basic and main construction drawings of the structural specialty; the design of mains, lighting, electricity, evacuation, air conditioning, fire protection, lightning protection and grounding for the electrical specialty; Professional gas pipeline layout; heating and ventilation professional office buildings and cafeteria heating, changing rooms, bathrooms, distribution rooms and kitchen ventilation, air conditioning in the main rooms of office buildings and canteens, smoke exhaust on the second and third floor of office buildings; Drainage professional domestic water supply system; domestic drainage system; hot water system; rainwater system; hydrant water supply system; automatic sprinkler water supply system; fire extinguisher configuration and so on.
  • This project is a Chinese-style commercial construction project in Ningxia. The number of floors is 3 floors above ground, 1 floor underground, the building height is 11.8 meters, and the building area is 2475.26 square meters. The underground building area is 725.06 square meters, and the structural form is a frame structure. , The design life is 50 years. The drawings include architectural design instructions, energy-saving design articles, general floor plans, floor plans, elevations, sections, detailed stairs, large-scale bathroom plans, enlarged views of facade components, large-scale wall drawings, and detailed windows and doors; Structural design instructions, foundation raft reinforcement diagrams, column reinforcement diagrams, beam reinforcement diagrams, plate reinforcement diagrams, and staircase detailed drawings; water supply and drainage design instructions, water supply and drainage, fire hydrant, spray floor plans, system diagrams; HVAC design Description, main line and equipotential bonding, lighting, fire alarm floor plan, system diagram.
  • Yuanshan Impression Ecological Leisure Village-comprehensive building construction, structure, water supply and drainage, electrical construction drawings. The total construction area is 1305.58m, with a total of 2 floors, 1 part underground, and a sloped roof. The height of each floor is 3.6 meters, the height of the second floor is 3.6 meters, and the building height is 7.2 meters. The building structure is a steel frame structure. Contents include building level, elevation, section view, building description, large-scale staircase, bathroom large-scale drawing and structure description, foundation level, section construction drawing, column, beam-level construction drawing, floor plan, column foot anchor layout, Structural floor plan, roof purlin layout and water supply and drainage design instructions, water supply and drainage plan, water supply and drainage system schematic, water supply and drainage large-scale drawings, axonometric drawings and electrical instructions, main electrical equipment tables, electrical system drawings, sockets, lighting , Weak current plan, roof lightning protection plan, foundation ground plan.
  • This project is a construction project of a commercial square in Ningxia. The building has 15 floors, one underground, a building height of 59.6 meters, a building area of 14,546 square meters, a structural form of a frame structure, and a design life of 50 years. The drawings include architectural descriptions, vertical sectional views, floor and elevator details, bathroom details, doors and windows details; structural descriptions, shear wall, column plan views, edge member node diagrams, beam and plate reinforcement diagrams, and staircase details; Water supply and drainage instructions, water supply and drainage, firefighting, sprinkler floor plans, private rooms, apartment water supply and drainage large-scale drawings, water supply and drainage, fire hydrants, sprinkler system diagrams; HVAC instructions, heating, heating mains, ventilation smoke exhaust plan, system diagrams; Electrical description, main line, lighting, weak current and fire door monitoring, automatic fire alarm, lightning protection and ground plan, system diagram.
  • A construction plan for a rehabilitation project for a disabled person in construction, structure, electrical, water supply and drainage, with a total construction area of 7083.32 square meters, 5 floors above the ground, 20.4 meters high, frame structure; the contents of the drawings include: architectural specialty, general description of architectural design, engineering Practice sheet, energy-saving design of public buildings, building plans, elevations, section views, elevator shaft large-scale drawings, bathroom large-scale drawings, large-scale stairs drawings, large-scale stairs railings, large-scale stairs stairs, sectional views, Outdoor fire pool plan, elevation, section, door and window table, door and window large sample, fire pool stair large sample drawing, node large sample drawing, outdoor auxiliary detailed drawing; professional structure, structural design general description, pile and pier structure detailed drawing , Foundation roof ~ 4.15, 4.15 ~ roof, roof ~ partial roof column plan, 4.15, 8.05, 11.95, 15.85, roof, partial roof beam flat construction drawing, foundation plan, foundation details, 4.15, 8.05 , 11.9, 15.85 plan of roof structure, large-scale drawing of staircase, detailed drawing of structure of outdoor fire-fighting pool, water supply and drainage specialty, water supply and drainage design instructions, spraying plan, level of water supply and drainage Floor plan, outdoor water supply and drainage general plan, indoor sewage general plan, outdoor rain water general plan, sprinkler system diagram, hydrant system diagram, sewage system diagram, sump system diagram, water supply system diagram, fire pump room water supply and drainage plan, system Map, detailed drawing of toilet water supply and drainage; electrical major, electrical seismic design, emergency lighting instructions, electrical system diagram, roof power distribution plan, roof lightning protection plan, fire pump room electrical plan, electrical construction drawing design description, lighting plan, socket plan , Weak current plan, ground plan.
  • A full-scale professional construction drawing of a middle-to-high-level nursing home (including the feedback opinion sheet and calculation book), including nursing homes 1, 2 and a community health center. The seismic fortification intensity is 6 degrees, and the main structural form is the frame shear wall structure of the nursing home 1, the nursing home 2 and the community health center are frame structures. The nursing home 1 has a building height of 25.2 meters, 8 floors above the ground, and a building area of 7194.63 square meters (including insulation); the nursing home 2 has a building height of 18.8 meters, 6 floors above the ground, and a building area of 1426.31 square meters (counting The insulation height of the community health center is 13.3 meters, the number of above-ground floors is 3, and the building area is 2386.66 square meters (including the insulation layer). The contents of the drawings include: building instructions, energy-saving articles, floor plans, elevations, section views, large-scale drawings of staircases, enlarged plans of units, detailed drawings of nodes, enlarged views of kitchens and bathrooms, detailed drawings of walls, and enlarged views of facades of doors and windows; Water supply and drainage instructions, water supply and drainage, firefighting plan, sprinkler floor plan, water supply and hydrant system diagram, water supply and drainage system diagram, water supply and drainage system diagram, solar system schematic diagram, kitchen bathroom water supply and drainage detailed diagram, pump room system diagram; structure Description, plan layout of pile position, plan of foundation layout, layout of wall and column structure, detail of frame column, reinforcement, beam construction method, detail of node, detail of stairs; electrical description, fire alarm construction design instruction, System diagrams and legends, weak current construction design instructions and legends, low-voltage mains system diagrams, low-voltage power distribution system diagrams, detailed distribution room and strong power well diagrams, weak current system diagrams, distribution box system diagrams, power floor plans, lighting floor plans, roofs Lightning protection plan, foundation ground plan, fire alarm plan, weak current plan; HVAC instructions, indoor heating riser system diagram, heating level Figure, heating large drawing and so on. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • This design is an outdoor project for a first-age nursing home, including the design of water supply pipes, hot water pipes, reclaimed water pipes, fire protection pipes, rainwater and sewage drainage pipes. Outdoor green water uses micro-irrigation. The practice is detailed in landscape. The valve water well is reserved in the picture. Rainwater is discharged into the planned municipal trunk rainwater pipeline on the south side of the plot and the municipal rainwater pipeline on the east side of the plot. The outdoor rainwater volume is 800L / S. The sewage is discharged to the municipal sewage pipe on the south side of the plot. The drainage system is a confluence of sewage and waste. The fecal sewage is discharged to the municipal sewage pipe network after being treated by the outdoor septic tank. The oily sewage in the kitchen is discharged to the municipal sewage pipe network after being treated by the outdoor oil trap. Medical water is discharged separately and discharged to the municipal sewage pipe network after treatment. The fire-fighting pool and fire pump room are located on the ground floor of Building 14. The fire-fighting pool stores the largest amount of water used by the fire hydrant and sprinkler in the building. The indoor fire hydrant uses 30L / s water, the fire lasts 3 hours (except for building 14 for building fires, the duration is 2 hours), and the storage water volume is 324m3; The amount of stored water is 108m3. The fire water storage capacity is 432m3. The fire pump room is provided with a constant pressure tangential hydrant pump and a constant pressure tangential spray pump. The fire hydrant water storage capacity of the fire hydrant for 10 minutes is 36m3, which is located in the water tank room on the roof of Building 14. There are one set of fire hydrant and spray voltage stabilization equipment in the water tank. Hot water system: District D (Building 14) uses a centralized hot water supply system, and the hot water engine room is located on the first floor of Building 14 (for Building 14); Areas A and B use a regional centralized hot water supply system, and Area A The hot water machine room and the hot water machine room in Zone B are both located in Building 13 (from Building 13 to Buildings 1 to 4, 15 and Building B to 5 to 12, 16 respectively). The content includes the general plan of the outdoor integrated pipe network, the cross-sectional view of the outdoor integrated pipe network, the design description and the material table, the general plan of the water supply, hot water, reclaimed water and fire protection pipes, and the general plan of the drainage pipe.
  • This project is a professional construction drawing of an all-buried civil air defense and basement of an international hospital. The total construction area is 70601.32 square meters. The underground construction area of the project is 3600.4 square meters and the underground is 3 floors. It is an underground parking garage and equipment room in peacetime and a shelter for second-class personnel in wartime. The contents of the drawings include architecture majors: civil air defense design instructions, material practice tables, room practice tables, civil air defense, fire partition diagrams, floor plans, floor plans, section plans, core tubes, and civil air defense detailed plans; structural majors: civil air defense structure design General description, pile layout plan, foundation layout, wall and pillar structure plan, roof beam structure plan, foundation section, pile detail, underground outdoor wall detail, civil defense door and window detail, civil defense shaft detail, stair structure detail And electrical, HVAC, water supply and drainage professional drawings.
  • A tumor hospital radiotherapy center and medical and medical technology room construction project, with a total construction area of 17,303 square meters, 9 floors above ground and 1 underground, the maximum building elevation is 40.2 meters; the curtain wall area is about 9700 square meters, and the door and window area is about 1300 square meters. The form is: the main building adopts a reinforced concrete frame-shear wall structure system, and the corridor adopts a reinforced concrete frame structure system. The contents of the drawings include: construction design instructions for the curtain wall project, building plans, elevations, elevation index drawings, large-scale curtain wall drawings, awning large-scale drawings, large-scale light roof drawings, large-scale doors and windows large-scale drawings, curtain wall node detailed drawings, buried Floor plan, floor plan of machine room, roof floor, large-scale drawings of embedded parts, general description of steel structure design, floor plan of awning steel structure and main building windows, exposed glass curtain wall, corridor windows, aluminum panel curtain wall, stone Curtain wall, glass lighting roof, glass canopy design calculation book, mechanical and other physical performance analysis of commonly used materials, appendix documents.
  • The new construction project of a county people's hospital, a psychiatric hospital, has a base area of 5450.0 square meters and a total construction area of 19936.9 square meters, of which the ground level is 19413.9 square meters and the underground is 523 square meters. There are 336 beds, including 294 in psychiatry and 42 in general. There are six floors above ground and one underground, with a height of 23.7m. The structural form is a reinforced concrete frame structure. Design scope: general floor plan, fire and greening general plan, building description, energy-saving chapter, green building chapter, vertical section view, bathroom details, floor elevator details, wall prototypes, node details, doors and windows Table and large sample and structure description, pile position plan, floor beam cap layout, cap detail, foundation ground beam, wall, slab, column plan, wall, column reinforcement, structure plan, Beam reinforcement diagram, stair plan layout, stair detail and water supply and drainage instructions, water supply and drainage, fire hydrant, automatic sprinkler floor plan, cold water main pipe system schematic diagram, hot water system schematic diagram, water supply, fire hydrant, automatic sprinkler system principle Drawings, large-scale drawings of water supply and drainage for firefighting and domestic pumping houses, electrical instructions, power distribution, lighting, roof lightning protection, grounding plan, substation high-distribution line diagram, vertical power distribution system, low-voltage power distribution system Figures, equipment layout of transformer substations, indirect layout of transformer substations, low-voltage distribution energy consumption monitoring system diagrams and HVAC instructions, main equipment material tables and installation details, smoke exhaust ventilation Plane, air-conditioning refrigerant pipes and condensate pipe plane, FIG smoke control system, multi-air conditioning system of FIG.
  • Construction, structure, water supply and drainage, and electrical construction drawings of the general building of the Xiaosong Town Health Center. There are 3 floors above the ground, the building height is 10.8m, and the building area is 3480 square meters. The building structure is a reinforced concrete frame structure.
  • Architectural, structural, electrical, and HVAC construction drawings for the medical and technical building of Jinzhou Traditional Chinese Medicine Hospital. Main functions: outpatient. The building covers an area of 836.28 square meters, with a total construction area of 4538.0 square meters. There are 5 floors above the ground and 3 floors partially , Building height: 20.7 meters. Structure type: frame structure. Contents include green building instructions, general floor plans, building energy-saving design instructions, engineering practices, door and window tables, floor plans, elevations, section views, large-scale staircase drawings, large-scale elevator room drawings, large-scale bathroom drawings, detailed pipe interlayer drawings, Large-scale wall drawings, green building and energy-saving calculation books and structural descriptions, flat foundations, section views, KZ floor plans, column tables, beams, plate reinforcement diagrams, indoor and outdoor staircase reinforcement diagrams and electrical instructions, sevoflurane gas Fire alarm system diagram, power distribution trunk system diagram, fire emergency lighting description and system diagram, integrated wiring, monitoring system diagram, fire alarm system diagram, integrated wiring, monitoring system diagram, fire alarm, cable plan, lighting, socket, weak current plan , Automatic fire alarm plan, roof lightning protection plan, foundation ground plan and air conditioning design and construction instructions, air conditioning plan, air conditioning system diagram
  • This project is a professional construction drawing of a primary school—composite building A building, structure, water supply and drainage, with a total construction area of 1490.19 square meters, 3 floors above ground, 11.7 meters high, and a frame structure; the contents of the drawings include: architectural specialty, general floor plan, and construction General design description, building decoration and construction table, green building design evaluation table, building energy-saving design description, first, second and third floor plans, stairwell roofing floor plan, roof plan, building elevation, section, window sill , Cornice, large-scale drawing of bathroom, statistics of doors and windows, large-scale drawing of staircase; structural specialty, general description of structural design, basic floor plan and basic reinforcement diagram, staircase structure reinforcement diagram, ground beam reinforcement diagram, ± 0.00 to 3.9 Meter floor, 3.9 to 7.8 m floor, 7.8 to 11.7 m floor column reinforcement diagram, stairwell roof roof structure reinforcement chart, 3.9 m floor, 7.8 m floor, 11.7 m floor roof reinforcement chart, 3.9 m floor Reinforcement drawings for beams of 7.8 meters, 11.7 meters; beam and drainage majors, general floor plan for water supply and drainage, indoor water supply and drainage design, construction instructions, material tables, floor plans for water supply and drainage for the first, second, and third floors, and roof floor supply drain Floor plan, roof floor water supply and drainage plan, water supply system schematic diagram.
  • The construction drawings (including calculation books, energy-saving design tables, and engineering survey report tables) of a low-level kindergarten, including a transmission room, the seismic fortification intensity is 7 degrees, and the main structural form is a frame structure. Among them, the building height of the kindergarten is 12.3 meters (height from the outdoor floor to the roof layer), and the number of floors above ground is 3; the building height of the transfer room is 4.2 meters (from the height of the outdoor design ground to the roof), and the number of floors above the ground is 1; the total construction area It is 8765 square meters (including 65 square meters of transmission room). The floor area ratio is 0.82, the building density is 28.5%, the greening rate is 35%, and the number of motor vehicle parking spaces is 28. The contents of the drawings include: building description, building energy-saving design, general plan, floor plan, elevation, section, staircase detail, dining ladder detail, toilet detail, node detail; water supply and drainage instructions, outdoor water supply and drainage, and Firefighting general plan, outdoor rainwater general plan, outdoor sewage general plan, water supply and drainage and fire hydrant plan self-spraying plan, water system schematic, solar system schematic, domestic sewage, wastewater system schematic, rainwater system schematic, air conditioning condensate system Schematic diagram, automatic sprinkler system schematic diagram, fire hydrant water supply system schematic diagram, water supply and drainage large-scale diagram, socketed engineering plastic pipe strip foundation diagram and concrete package diagram; structural description, general description and detailed drawings of the envelope structure, Schematic layout of the envelope structure, pile plan, foundation plan, flat construction drawing, reinforcement diagram, staircase detail, node detail diagram, schematic layout of the envelope structure, general description and details of the envelope structure; electrical instructions, Automatic fire alarm instructions, electrical floor plan, power distribution system diagram, fire floor plan, fire alarm system schematic diagram, power distribution Line system diagram, power distribution system diagram, power distribution plan, power distribution plan, lighting plan, roof lightning protection plan, ground plan, sub-metering, electrical fire, fire door, fire power monitoring system, kitchen Electrical floor plan; HVAC description, ventilation floor plan; landscaping description, planting design description, arbor planting plan, shrub planting plan, vertical design plan, paving and park road details, standard parking space details, sketch plan; decoration Description, floor plan, ceiling layout, floor layout, ceiling size, luminaire size, partition wall size, elevation index, elevation, node sample, etc. Specialties include architecture, structure, water supply and drainage, electrical, heating and ventilation, landscape greening, decoration, and foundation pit maintenance.
  • This project is a construction and structural construction drawing of a middle school expansion of a high school teaching building and dormitory building project. Among them, the teaching building has a total construction area of 6206.68 square meters, 4 floors above the ground, a height of 17.65 meters, and a frame structure. The dormitory building has a total construction area of 6085.47 square meters. , 4 floors above ground, 16.05 meters high, frame structure; the contents of the drawings include: architectural majors, architectural engineering design instructions, engineering practice tables, green design chapters of architectural construction drawings, architectural floor plans, elevations, section views, and dormitory unit plan details Plan, detailed plan of barrier-free dormitory, detailed plan of toilet and toilet, large nodes, windows and doors, windows and doors, large wall, large bathroom, detailed description of prefabricated building, floor plan of prefabricated interior wall; structure Major, general description of structural design, flat method changes and supplementary explanations, detailed drawings of pitched roof nodes, basement engineering structure design instructions, green design special (structure), basic structure plan, column plan construction drawing, structure plan, ground beam plan Construction drawings, beam flat construction drawings, stair details, large-scale wall samples, special instructions for assembled structures, large-scale drawings of typical components Prefabricated floorplan prefabricated interior floor plan design foundation pit construction general description, branched Support sectional view, a detail, plan view of the foundation pit.
  • Multi-professional construction drawings of a low-rise kindergarten, including door guards and power distribution rooms, the main structural form is a frame structure. The height of the guard building is 4.5 meters, the number of floors above the ground is 40.5 square meters, the building height of the power distribution room is 4.95 meters, the number of floors above the ground is 41.9 square meters, the height of the kindergarten building is 12.1 meters above the ground, The number of floors is 3 floors, and the underground part is 1 floor. The total construction area is 8717.6 square meters, of which the floor construction area is 8373.6 square meters and the underground construction area is 344 square meters. The contents of the drawings include: building description, energy-saving design, floor plan, elevation view, section view, section of the children's activity unit, section of the lecture hall, details of the stairs, node details, doors and windows details, bathroom details; water supply and drainage Description, outdoor water supply and drainage general plan, water supply and drainage plan, spraying plan, water supply and drainage system schematic diagram, pump room large scale drawing, kitchen large scale drawing, bathroom large scale drawing; electrical instructions, fire alarm electrical design and construction instructions, low voltage distribution Electrical schematic diagram, vertical electrical main line diagram, itemized energy consumption measurement system diagram, electrical system diagram, general plan of electric vehicle charging system layout, electrical plan, roof lightning protection plan, foundation ground plan, fire alarm system diagram, electrical fire monitoring system Figure, fire door monitoring system diagram, fire power monitoring system diagram, fire door monitoring installation diagram, fire alarm plan, distribution cabinet layout, lighting plan; HVAC instructions, ventilation plan, etc. Specialties include construction, water supply and drainage, electrical, heating and ventilation.
  • Full-scale construction drawings (including calculation books) of a high-level university teaching and research building, the seismic fortification intensity is 6 degrees, the main structural form is a frame core tube structure, the building height is 99.9 meters, the number of above-ground floors is 25, and the number of underground floors is 3. The total construction area is 78670.97 square meters. The contents of the drawing include: building description, general description of green building and energy-saving design, general description of construction design of civil air defense building, general floor plan, floor plan, elevation view, cross-section view, wartime floor plan of the underground floor, comprehensive pipeline protection closed casing of the air defense zone. Buried layout plan, combined floor-to-floor plan, large staircase plan, core tube plan, driveway plan, civil air defense mouth plan, bathroom plan, wall plan, door and window tables; water supply and drainage Description, gas fire extinguishing system design description, water supply and drainage plan, fire hydrant plan, automatic sprinkler plan, living water supply system schematic, underground garage flushing water supply pipe system schematic, domestic hot water system schematic, fire hydrant system schematic, automatic sprinkler System schematic diagram, circulating cooling water system schematic diagram, drainage system schematic diagram; structural description, design and construction instructions for artificial digging cast-in-place piles, design instructions for civil air defense structures, design and construction instructions for bonded prestressed beams and slabs, plan layout of pile foundations, Floor layout, floor plan structure layout plan, flat construction drawing, large-scale outdoor wall drawing, civil air defense opening Large-scale drawing, large-scale drawing of driveway, large-scale drawing of staircase, large-scale drawing of wide flat beam structure; electrical description, civil air defense design description, automatic fire alarm and fire-fighting linkage system design description, weak current floor plan, power distribution system drawing, vertical trunk line System diagram, floor plan of transformer substation, large-scale drawing of cable trench, large-scale drawing of air-conditioning control room and electric well, energy consumption monitoring, power monitoring system design description and networking concept diagram, basement grounding plan, roof lightning protection Floor plan, power and trunk plan, lighting floor plan, automatic fire alarm and linkage control system diagram, electrical fire monitoring system diagram, fire power monitoring system and instructions, fire door monitoring system and instructions, fire alarm floor plan, civil defense main line system diagram, civil defense Pipeline enclosure construction method, detailed drawings of closed ribs and resistance sheets, detailed signal of ventilation mode; HVAC description, plan of ventilation and smoke exhaust, floor plan of air conditioning, large-scale drawing of air conditioning, diagram of pressurized air supply system and so on. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • The construction drawing of a demolition and construction project of a low-level auxiliary kindergarten, the seismic fortification intensity is 6 degrees, and the main structural form is a frame structure; the building height is 12 meters, the number of floors above the ground is 3, and the number of underground floors is 1; the floor area of the kindergarten is 2627.2 square meters Meters, the basement area is 86.77 square meters, another fire fighting pool area is 113.05 square meters, and the gate guard and consumer control room above-ground construction area is 35.75 square meters. The contents of the drawings include: architectural design description, green building design description, building energy-saving design table, construction positioning general plan, doorman building plan, kindergarten basement plan, kindergarten plan, kindergarten elevation view, kindergarten section view, staircase details, bathroom details , Node detail drawings; water supply and drainage instructions, water supply and drainage construction drawings, construction instructions, water supply and drainage construction drawings, energy-saving design instructions, outdoor water supply and drainage general plans, outdoor water supply general plans, outdoor sewage general plans, outdoor rain general plans, water supply and drainage plans, spray Drainage plan, large-scale drawing of water supply and drainage in the pump room, schematic drawing of drainage system of the sump, large-scale drawing of water supply and drainage in the toilet, schematic drawing of water supply and drainage system, schematic drawing of rainwater system; structure description, basic floor plan, flat construction drawing, Structural floor plan, structural construction drawing, staircase construction drawing, node detail drawing, door guard structure construction drawing; electrical description, fire automatic alarm system construction drawing design description, public building construction drawing energy saving (green building) design description, weak electricity intelligent design description , Outdoor electrical general plan, room General plan of power consumption, general plan of outdoor weak current, detailed drawing of cable well, power cable laying section, automatic fire alarm system, automatic fire alarm plan, power distribution system, ground plan, electrical plan, lighting plan, lightning protection plan, Comprehensive wiring, computer network system diagram, Internet, equipment network, video surveillance system diagram, background music system diagram, perimeter prevention system diagram, multimedia teaching system diagram, multimedia conference system diagram, electronic patrol system diagram, computer room engineering system diagram, Weak current floor plan; ventilation design and construction instructions, kindergarten basement ventilation floor plan, toilet ventilation floor plan; landscape design description, plant design description, landscape greening general plan, green space area calculation plan, grid positioning general plan, size positioning general plan, vertical design General floor plan, general floor plan of paving, indexing, general floor plan of wall positioning, general floor plan of facility layout, detailed entrance floor plan, lighting selection plan, furniture selection plan, children's playground details, paddling pool details, flag raising platform Detail, ecological parking Drawings, detailed wall details, transparent wall details, general plans, greening plan, plant plan; decorative instructions, floor plan, top plan, floor plan, lamp positioning plan, hall elevation view, bathroom Elevation view, activity room, picture book room, sound room elevation view, node detail drawing, door table drawing, door node large sample drawing, etc. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation, landscape, decoration.
  • The main school building and logistics auxiliary building of a new campus construction project of a vocational and technical college. The main teaching building has 6 floors above ground and 1 basement floor, with a total construction area of 29880 square meters and a building height of 23.85m. The logistics subsidiary building has 4 floors above ground and 1 basement floor. The building area is 27769.3㎡, the building height is 22.4m, the frame structure, and the seismic fortification intensity is 6 degrees. The main teaching building contains: architectural design instructions, energy-saving design articles, vertical section views, large-scale classroom drawings, bathroom elevator stairs details ; Structural design instructions, basic floor plan, detailed foundation drawings, beam and slab reinforcement diagrams for each floor, wall and column positioning diagrams, staircase structure diagrams; water supply and drainage design instructions, pump room layout, water supply and drainage large-scale and system diagrams, negative One floor water supply and drainage and sprinkler floor plan, each floor water supply and drainage floor plan, fire water supply system diagram, automatic sprinkler system diagram; electrical design description, fire automatic alarm design description, power distribution system diagram, weak current trunk system diagram, automatic alarm and Firefighting linkage control system diagram, hydrant start pump button wiring diagram, power distribution box deployment diagram, power, lighting, socket, weak current floor plan of each floor, minus one Floor automatic alarm plan and so on. The logistic annex building contains: water supply and drainage design instructions, catalog, main equipment material table, legend table, negative floor spraying, water supply and drainage floor plan, water supply and drainage floor plan of each floor, water supply and drainage system diagram; electrical design description, power distribution box expansion plan One, negative floor electric power, lighting floor plan, each floor electric power, lighting, weak current floor plan, roof floor lightning protection floor plan, fire alarm and linkage control design description, fire alarm and linkage control system diagram, negative floor fire automatic alarm floor plan, system Figures; basic design instructions, ground floor plan, ground beam floor plan, beam and plate reinforcement plan, wall and column floor plan (general description of missing structure design)
  • This project is a construction drawing and effect drawing of a kindergarten affiliated kindergarten in a central elementary school, including construction, structure, water supply and drainage, electrical, HVAC, landscape and interior decoration. The total land area is 3,624.14 square meters, and the area of the above-ground building (teaching room and gatekeeper and consumer control) 2466.86 square meters, excluding buildings (basement, outdoor fire pool, overhead activity venue) area of 431.63 square meters, children's playground (outdoor activity venue, overhead activity venue) area of 652 square meters, building floors, height: 1 floor above the guard , The building height is 3.8 meters, the fire height is 3.95 meters; 3 floors above the teaching building, 1 underground, the building height is 12 meters, the fire height is 12.175 meters; the outdoor pool, 1 underground; the building structure is a frame structure, and the seismic fortification intensity It is 6 degrees; the contents of the drawings include: architectural majors, general floor plans, general architectural design instructions, floor plans for the doorman, roof plans, elevations, section views, large node samples, large doors and windows for teaching rooms, energy-saving meters, basements And outdoor fire pools, first, second and third floors, roof plans, building elevations, section views, staircase details, Large samples of bathrooms, detailed drawings of joints; structural specialty, general description of structural design, construction plans of foundation beams, floor plan of first, second, third, roof floor structures, construction plans of wall columns, construction plans of column methods, construction plans of beam methods 、 Details of stairs, details of nodes, floor plan of door guard, floor plan of pool structure; HVAC specialty, ventilation design and construction instructions, basement ventilation floor plan, bathroom ventilation floor plan, first floor ventilation plan; electrical specialty, outdoor strong electricity design description, outdoor lighting Power distribution system diagram, cable well large-scale drawing, street lamp basic detailed drawing, outdoor strong electricity general floor plan, teaching room electrical design instruction, equipment material table, power distribution system drawing, vertical system drawing, basement electrical floor plan, basement grounding plan 、 Internal layout drawing of generator room, low-voltage power distribution system drawing of generator set, first, second and third floor electrical floor plans, roof lightning protection plan, foundation ground plan, automatic fire alarm design instruction, equipment material table, layout of interior control room, fire Automatic alarm system diagram, basement fire automatic alarm plan, fire door monitoring General plan, fire control equipment power monitoring system diagram, first, second and third floor fire automatic alarm floor plan, roof fire automatic alarm floor plan, outdoor weak current general floor plan, general description of intelligent system design, door guard first floor weak current floor plan, main equipment material table, Weak current system diagram, weak current floor plan, etc., as well as water supply and drainage specialty, interior decoration, landscape design and construction drawings, and overall effect drawings.
  • The decoration construction drawing of a high-rise hotel, the seismic fortification intensity is 7 degrees, and the main structural forms are the partial frame structure of the podium and the core tube structure of the tower. The building height is 99.9 meters, the number of above-ground floors is 24, the number of underground floors is 1, and the total construction area is 4,7742.8 square meters. The contents of the drawings include: decoration instructions, design instructions for the fire resistance rating of the decoration materials, floor plans of fire partitions, furniture layouts and positioning plans, ceiling layouts and positioning plans, floor finishes and positioning plans, building wall positioning plans, ceiling shapes and Fixture positioning map, ground pavement and positioning map, decorative finish positioning and elevation index map, elevation map, node map, door table, decoration material construction method table; electrical description, TV network, network wiring system diagram, voice wiring System diagram, video surveillance system diagram, cable TV system diagram, data machine room floor diagram, monitoring machine room floor diagram, access control management system diagram, banquet hall sound reinforcement display system diagram, floor plan, banquet hall stage lighting system diagram, floor plan, conference room audio Video system diagram, floor plan, information release system diagram, floor plan, security floor plan, integrated wiring floor plan, etc. Majors include architecture, electrical, and decoration.
  • The construction drawing of a super high-rise hotel (including the building energy-saving design report and insulation check calculation book), the seismic fortification intensity is 6 degrees, and the main structural form is the frame core tube structure. The building height (fire fighting height) is 131.1 meters, the planned height is 148.1 meters; the number of floors above ground is 30, and the number of underground floors is 1; the total land area is 27692.68 square meters, and the total construction area is 145386.6 square meters, of which the building area is 80073.32 square meters, the base area of this building is 9958.89 square meters. The contents of the drawings include: building description, energy-saving design, green building design, floor plan, elevation, section, large-scale plan of stairs, cross-section of stairs, schematic diagram of separation of doors and windows, construction drawing of basement.
  • The construction plan of a low-rise hotel in Sichuan Province, with a planned total building area of 35917.13 square meters, including guest rooms (87 buildings), public areas and spa parts. The seismic fortification intensity is 8 degrees, and the main structure type is a frame structure, in which the ground floor of the hotel public area A has 2 floors, the building height is 11.22 meters, and the building area is 2294.94 square meters; the ground floor of the hotel public area B has 2 floors, and the underground floor Number of 3 floors, building height of 25.96 meters, construction area of 6193.94 square meters; SPA above-ground layers of 3 layers, building height of 15.15 meters, construction area of 3747.83 square meters; 1-story above-ground cloth floor, building height of 3.8 meters, construction area of 62.37 Square meters. The contents of the drawings include: building description, energy saving description, hotel general plan, floor plan, elevation view, section view, large-scale staircase diagram, large-scale node diagram, large-scale diagram of bathroom, locker room, large-scale diagram of doors and windows, and windows and doors, technology Table of measures.
  • Construction drawing of a middle-to-high-rise cultural resort hotel in Jiangsu Province. The seismic fortification intensity is 6 degrees. The main structure type is a reinforced concrete frame structure with 9 floors above ground and 1 underground floor. The building height is 48.9 meters and the building area is 95036.85. Square meters. The contents of the drawings include: general description of architectural and structural design, vertical sectional views, detailed stairs, door and window details, node details, wall details, energy saving design for public buildings, green design, toilet details, rain Shed large-scale drawing, car ramp detailed drawing, wind well large drawing, door and window table, roof plan, room detail drawing, member section table, truss elevation view, member arrangement drawing, axonometric drawing, member Plan view of foundation, plan view of truss, plan view of member support, plan view of dome, plan view of vertical member, plan view of formwork and plate reinforcement, plan view of pile position and platform arrangement, detailed view of pile body, description of pile foundation, detailed view of platform foundation, Shear wall detail, frame column detail, template drawing. Majors include architecture and structure.
  • CBD Jialong Building. Including construction professional vertical section and node detailed drawings; structural professional foundation and main body construction drawings; HVAC professional ventilation and smoke exhaust system, variable frequency one drag multiple variable refrigerant flow air conditioning system for commercial part of podium. Water supply and drainage professional life water supply, domestic sewage system, rainwater and air conditioning condensation drainage system, fire hydrant system, fire extinguisher configuration.
  • A hotel project in Jilin Province with 6 floors above ground and 1 underground floor with a total construction area of 46451.19㎡ and a building height of 24m; the structural form is a frame structure, and the drawings include: architectural design instructions, floor plans for each floor, schematic diagrams of fire protection zones, elevation sections, and axes Enlarged detailed drawings, detailed drawings of the core of the staircase elevator, detailed drawings of the ramp, etc .; Structural design instructions, flat construction drawings of each floor beam plate, column wall layout drawings, construction drawings of the basement roof beam roof structure, floor reinforcement design; water supply and drainage design instructions , Floor plan of water supply and drainage of each floor, floor plan of shower, large-scale drawing of bathroom, water supply and drainage system, rain system, fire hydrant, sprinkler system, etc .; HVAC design instructions, HVAC schematic diagram, underground floor ventilation plan , Floor plan of air-conditioning wind and air-conditioning water system on each floor, floor plan of geothermal coil, large-scale drawing of tube well and system drawing, etc .; construction drawings of electrical and steel structures, etc.
  • This drawing is the reception center of Ga Hot Spring Hotel in Dalian Napa Valley Hot Spring Hotel. It has 3 floors above ground and 4 floors above ground. The above-ground building area is 2275.33 square meters, the underground building area is 387.79 square meters, frame structure, and partial basement. Including construction, structure, water supply and drainage, HVAC, electrical construction drawings. (Missing: water supply and drainage system diagrams and hydrant system diagrams)
  • The project is a construction project of a Wanda City hotel in Jiangsu, which includes four-star hotel A, four-star hotel B, and six-star hotel C. The number of building floors is 8, 9, and 3, and the ground floor is 1 and the building heights are 45.7. , 47.63, 23.95 meters, the building area is 42561.66, 45259.6, 49152.89 square meters, the structure forms are frame shear, frame, frame structure. The drawings include architectural design instructions, fire special chapters, green special chapters, general floor plans, plan elevation sections, schematic diagrams of fire protection zones, large-scale elevation drawings, guest room areas along the lake, courtyard elevations, various guest room details, boiler rooms , Living pool, fire fighting pool, high and low voltage substation, refrigeration heat exchange machine room plan details, stairs, bathroom, linen room, walls, doors and windows details; structural professional, water supply and drainage professional, HVAC professional, electrical professional drawings (Missing drawings for hotel B stairs).
  • Multi-professional construction drawings of a low-rise clubhouse, the seismic fortification intensity is 7 degrees, the main structural form is a shear wall structure, the building height is 9.8 meters, the number of above-ground floors is 1, the number of underground floors is 1, and the total construction area is 5,210 square meters. Among them, the floor area is 2,610 square meters, and the basement area is 2,600 square meters. The drawings include: building description, building energy-saving design, floor plan, elevation view, section view, driveway enlarged view, roof drainage schematic diagram, staircase enlarged view, elevator enlarged view, doors and windows enlarged elevation view, blowout well sectional view, bathroom enlarged view Figures, node details, curtain wall plan; structural description, general description of steel structure design, clubhouse awning structure layout, floor plan, reinforcement diagram, beam-column construction method, detailed stairs.
  • This project is the construction drawing of a certain Yaowang hot spring construction project, with a total construction area of 455.43 square meters, one floor above the ground, a main structure of 50 years, a structural form of a frame structure, and a building height of 3.75 meters; the contents of the drawings include: general plan, wall plan Arrangement drawing, general description of building design, building energy-saving design description, first-floor plan, roof plan, building elevation, section, indoor and outdoor decoration instruction form, daughter wall large-scale drawing, door and window separation large-scale drawing.
  • This project is a construction drawing of a city's grand theater. The total construction area is 12,991.52 square meters, with 3 floors above ground and 2 floors below ground. The main stage area has a height of 35.25 meters, the main roof area is 42.55 meters, and a Grade B theater. (800 seats), reinforced concrete frame structure. The contents of the drawings include: construction construction design instructions, building energy-saving design descriptions, building positioning plans, general floor plan, underground first floor, second floor plans, schematic diagrams of fire protection zoning, first to third floor plans, horse paths, sound bridges, and surface light bridges Floor plan, roof plan, top grid top plan, building elevation view, section view, elevator, stairs, bathroom large sample, car ramp large sample, door and window table, door and window detailed drawing, high and low voltage distribution room large sample, node large sample , Large-scale drawing of the wall, General description of structural design, Design description of bored cast-in-situ pile, Design description of steel structure, Single foundation, Large-scale pile cap, Large-scale layout of foundation, Large-scale layout of pile, Large-scale column layout, Reinforcement table for walls, columns, reinforcement plan for beam flat method, reinforcement plan for flat plate method, structural layout, glass layout, embedded layout, concrete structure layout, etc.
  • Rizhao Swimming Pool building level, elevation, section view, general plan, group plan schematic, stand details, stair details, bathroom details, node details, diving pool details, door and window tables and curtain wall details, building description and structure Description, pile location layout, manual digging pile detail, cap arrangement layout, foundation beam, plate reinforcement diagram, node detail diagram, column network location diagram, column and wall location diagram, steel structure node diagram, steel structure Floor plan, structural plan positioning, mesh shell node details, mesh shell element length table, mesh shell member number chart and element length table, mesh shell flat, section view, mesh shell embedded parts layout, horseway layout , Layout of column and brace support, column foot layout, ring truss plan, etc.
  • The project is a mass service center in a village and town in Guiyang, Guizhou. It has 3 floors above ground, a building height of 11.2 meters, a building area of 365.32 square meters, and a structural form of masonry structure. The designed service life is 50 years. The drawings include architectural design instructions, floor plans, elevations, section views, large-scale staircases, and large-scale bathroom prototypes; structural design instructions, basic floor plan, structural floor plans, floor reinforcements, and roof construction. Figures, detailed drawings of stairs; water supply and drainage design instructions, floor plans for each floor, water supply and drainage system drawings, toilet water supply and drainage samples, bathroom water supply and drainage system isometric drawings; electrical design instructions, floor power distribution plans, floor lighting plans , The floor plan of each floor weak current, the roof lightning protection and foundation ground plan, the distribution trunk system diagram, the weak current system diagram.
  • This project is a construction project of a national fitness activity center in a county in Ningxia, including a gymnasium and a stadium. The building layers are 1, 3, building heights are 28.95, 42.667 meters, and building areas are 20514.34 (among which, the underground building area is 3,293.38 square M), 12961.21 square meters, the structural forms are frame spherical grid steel structure, frame steel grid structure, the design service life is 50 years. The drawings include architectural design instructions, energy-saving design articles, general floor plans, vertical sectional views, fire-proof zoning plans, large-scale drawings of stairs, bathrooms, large-scale drawings of stands, site layout plans, large-scale drawings of walls, and detailed drawings of doors and windows; Structural design instructions, foundation construction drawings, beam, slab, column construction drawings, steel structure grid construction drawings; water supply and drainage professional, HVAC professional, electrical professional drawings.
  • The project is a civil air defense project in the basement of a certain science and technology center in Anhui. The civil air defense construction area is 4889 square meters. It is a Class B 6-level material warehouse in wartime, a car garage in normal time and a chemical protection level of D-grade. The drawings include architectural design instructions, general floor plan, basement peacetime, wartime, roof plan, large-scale drawings of air wells, large-scale drawings of civil air defense openings, large-scale drawings of door frame walls, large-scale drawings of explosion-proof wave cable wells, and sumps. Large-scale drawings; structural design instructions, basement wall plan layout plans, basement columns, beams, roof reinforcement plan, door frame wall reinforcement plan plans, ramp ramp plans; water supply and drainage design instructions, basement wartime water supply and drainage plan, Basement fire floor plan, sprinkler, fire hydrant system diagram, wartime material library water supply schematic diagram; HVAC design description, basement ordinary and wartime ventilation plan, wartime intake and exhaust air principle diagram; electrical design description, basement lighting, power distribution plan , Wartime defense and communication plan, wartime communication system diagram, etc.
  • This project is a construction project of an exhibition hall in Jiangsu. The building has 3 floors, 1 underground, a building height of 12.35 meters, and a building area of 1965.08 square meters, of which the underground building area is 643.52 square meters. The structural form is a frame structure. It is designed for use. The period is 50 years. The drawings include architectural design instructions, green design special articles, vertical section views, staircase details, bathroom details, curtain wall large-scale drawings, wall details, doors and windows details; structural design instructions, basic floor plan, column plan Reinforcement diagrams, beam plane reinforcement diagrams, structural plan diagrams, staircase details; water supply and drainage design instructions, water supply and drainage floor plans, toilet water supply and drainage large-scale drawings, system diagrams; HVAC design instructions, air conditioning and ventilation, water pipe plans; electrical design instructions, Electricity, lighting, firefighting, weak current floor plans, system diagrams (including curtain wall drawings, etc.).
  • The project is the construction, structure, and electrical construction drawings of the restaurant, dormitory building, and comprehensive building of a toll station road management office. The total construction area of the dormitory building is 1021.60 square meters, 2 floors above ground, 7.65 meters high, and a frame structure. The station building has a total construction area of 1055.42 square meters, 2 floors above ground, and a height of 10.35 meters; the restaurant corridor has a total construction area of 161.51 square meters and 19.9 square meters, a building height of 4.05 meters and 2.95 meters, a floor above the ground, and a frame structure. The contents of the drawings include: site maps, general floor plan, interchange interchange floor plans, general architectural design instructions, architectural floor plans, elevations, section views, building energy-saving design tables, door and window tables, wall details, men and women's toilet details Drawings, detailed drawings of walls, details of stairs, details of air-conditioning panels, details of outdoor decoration and accessories practices, details of cornices, canopies, details of stairwells, summary tables of energy-saving calculations, and composite relationship diagrams of restaurants and corridors in comprehensive buildings; structure Specialty, general description of structural design, basic floor plan, frame column plan, beam flat construction drawing, roof slab flat construction drawing, cast-in-place slab reinforcement drawing, staircase construction drawing; electrical specialty, electrical design description, distribution Electrical system diagram, weak current system diagram, power distribution plan, lighting plan, weak current plan, roof lightning protection plan, foundation ground plan, general power distribution plan, electromechanical system, weak current system pipeline plan, etc. Book, public building tradeoff calculation report, building energy saving design review filing form (cold areas of public buildings).
  • A toll station project for housing construction along a highway includes toll complex buildings, water distribution houses, and toll sheds, of which 3 floors above the toll complex building, a building area of 1549.99 square meters, a building height of 14.26m, and a reinforced concrete frame structure; Single-storey public building, with a construction area of 212.52㎡, a building height of 5.85m, a reinforced concrete frame structure; a toll booth construction height of 15.35m, and a reinforced concrete frame structure; the seismic fortification intensity is 7 degrees, and the drawings include: architectural design instructions, general leveling details Map, general plan view of cane toll station, vertical sectional view of tolling comprehensive building, bathroom detail dormitory detailed drawing, door and window table, large sample drawing of door and window, staircase detailed drawing, large wall drawing, water distribution room vertical sectional drawing, Door and window tables, door and window detailed drawings, toll greenhouse vertical sectional views; general description of structural design, slope roof beam drawing rules and structural details, basic floor plan, basic large-scale sample description, beam flat construction drawing, slab wall (column) Floor plan, structural floor plan, large-scale layout of stairs, floor plan of tollhouse foundation, flat construction drawing of beam, slab and column, electric door with flagpole at toll station
  • This project is a road drainage construction drawing for a rural construction pilot project. The main purpose of this project is to add sidewalk drainage ditch and street lighting to two completed main roads. The main works include: 1279 meters of new drainage ditch, 172226 square meters of sidewalk, 174 street lights installed; road grade: urban branch road; road design speed: 30km / h; design life of new road structure: 8 years; sidewalk surface structure: Concrete cushion walkway brick; road seismic fortification level: 7 degrees. The contents of the drawing include: drainage engineering design specification, drainage pipe excavation cross-section view, drainage pipe excavation cross-section view, drainage ditch cross-section view, cover plate drainage ditch section, cover plate drainage ditch profile, cover plate drainage ditch plane, cover Reinforcing board slab, heavy cover sheet material table, construction drawing of sloping wall, main material table, floor plan of drainage ditch, vertical section view of rainwater culvert, floor plan of rainwater pipe, schematic diagram of project location.
  • A construction drawing of a subway station equipment area lighting project. The design content of this drawing covers the lighting load power supply, control design and station outlet power distribution design in the station equipment area. The contents of the drawing include: design description, lighting distribution system diagram, lighting distribution box floor plan, emergency lighting power supply system diagram, EPS floor plan, and basic installation drawing, intelligent lighting control system schematic diagram, distribution box system diagram, Floor plan of the equipment floor of the hall floor, floor plan of the cable mezzanine floor of the equipment floor, floor plan of the floor floor equipment area, floor plan of the floor floor equipment area, floor plan of the floor floor equipment area evacuation instruction, floor plan of the floor floor equipment area evacuation instruction, floor plan of the floor floor of the office floor , Entrance and exit socket plan, platform floor socket plan, stairwell lighting cross-section schematic diagram, metal pipelines passing through walls, floor fire blocking diagram, main equipment material table, cable detail table, legend symbols
  • A multi-professional preliminary plan for a bid line section of a subway line (including the estimated budget, reply to countersigned comments, reply to consulting opinions, file registration form, document data collection form, and industrial planning section), the bid section includes 3 stations. The contents of the drawing include: building description, general plan (recommended), general plan (comparison), passenger flow attracting area analysis, fire protection zone diagram, plan view, section view, entrance and exit plan, section view, entrance and wind pavilion plan, section view, Vertical elevator plan, vertical elevator sectional view, air duct plan, sectional view; water supply and drainage instructions, outdoor water supply and drainage and firefighting general plan, water supply and drainage and firefighting plan, entrance and exit channel plan, water supply system schematic, drainage system schematic, wastewater pump room plan , Sewage pump room plan; structural description, stray current protection design description and steel bar welding requirements, general floor plan, geological longitudinal section view, main layout plan of the supporting structure, supporting plan layout, sectional view of the retaining structure, retaining piles Reinforcement diagram, steel support large-scale diagram, reinforcement diagram, monitoring floor plan, station monitoring general plan, and building protection plan, envelope structure monitoring section schematic diagram, station structure construction sequence diagram, station structure construction progress plan cross road diagram , Site layout and traffic relief reference map, underground pipeline relocation Change the reference plan, the plan layout of the station roof, middle plate, and floor structure, the main section of the station, the plan of the entrance and exit passages, the cross-sectional view, the plan and layout of the envelope structure of the entrance and exit passages, the cross-section view, the plan of the wind kiosk, the section围护结构平面布置图、剖面图,车站结构标准横断面防水图,施工缝防水设计图,变形缝防水设计图, 钢筋焊接示意图,测试端子、连接端子、排流端子制作安装图;动力照明说明,变电所低压主接线图,智能低压控制系统示意图,动力配电干线图,照明系统图,综合接地系统图,应急照明电源装置系统图,变电所低压开关柜系统排列图,环控电控室环控柜系统排列图,电气设备平面布置图;暖通说明,车站总平面图,隧道通风系统图,隧道通风系统平面图,车站大系统原理图,车站A端、B端小系统系统图,站台层大系统平面图,站厅层通风空调小系统平面图,射流风机平剖面 ,车站水系统系统图,水系统平面图,车站备用空调系统原理图,车站备用空调平面图等等。专业包括建筑、结构、给排水、动力照明、采暖通风。
  • 某地铁线1标段多专业初设图(含概预算、会签意见回复、咨询意见回复、文档数据收集表),包括3个地铁站。图纸内容含:建筑说明,总平面布置图,客流吸引范围分析图,客流吸引图,站厅层平面图,站台层平面图,站台板下层平面图,剖面图,出入口平剖面图,垂直电梯平剖面图,风道平剖面图,消防疏散楼梯平剖面图,风亭详图;给排水说明,室外给排水及水消防总平面图,给排水及水消防平面图,出入口给排水及水消防平面图,车站生产、生活及消防给水系统原理图,车站排水系统原理图,排水泵房平面布置图,消防泵房大样图(含系统图),车站生产、生活及消防给水系统原理图;结构说明,总平面图,地质纵断面图,围护结构平面图,围护结构纵断面图,围护结构横断面图,施工步序图,配筋图,钢围檩及冠梁大样图,监测断面图,监控量测平面图,建构筑物监测平面图,降水井点平面布置图,溶洞加固示意图,主体结构平面图、剖面图、断面图,主体结构横断面配筋通用图,风道结构图,出入口结构图,出入口风险源措施图,出入口监测平面图,标准横剖面防水图,施工缝防水设计图,变形缝防水设计图,变形缝收口及穿墙管等细部构造防水做法,明挖车站与明挖通道及盾构法区间接口防水图,防水材料及不同防水材料的节点过度构造详图,钢筋焊接要求,钢筋焊接示意图,车站纵断面结构钢筋焊接示意图,车站结构钢筋连接端子制作安装图,车站结构钢筋测量、排流端子制作安装图,车站中板开孔、风道、人行通道结构墙开孔钢筋焊接示意图;动力照明说明,变电所低压主接线图,智能低压及电气火灾监控系统图示意图,动力配电干线图,照明系统图,综合接地系统图,应急照明电源装置系统图,开关柜、环控柜系统排列图,电气设备平面布置图;暖通说明,总平面图,隧道通风系统图,大系统系统图,站台层隧道通风及大系统平面图,站台板下隧道通风平面图,东南端、西北端站厅层隧道通风及大系统机房平面图,东南端、西北端小系统系统图,站厅层小系统及其机房平面图,站台层小系统平面图,水系统系统图,东南端水系统平面图,西北端水系统及备用空调平面图,横剖面图等等。专业包括建筑、结构、给排水、动力照明、采暖通风。
  • Multi-professional construction drawings for the excavation section of the southern section of a subway station. This project is a two-level underground structure, the first underground level is a property development layer, and the second underground level is a track area. At the southern end of the excavation section, the ground floor has a construction area of 1275 square meters. There are subway equipment management rooms on the 11 '~ 13' axis, including ventilator rooms, weak motor rooms, environmental control electrical control rooms, anti-hiding door control rooms, etc .; 1 ' The ~ 11 'axis is a property development, connected to the public area of the south hall of the subway station, and separated by fire-proof roller shutters. There are 2 entrances and exits on the ground floor of the open section in the southern section, which are connected to the ground. Entrance. The contents of the drawings include: architectural instructions, door and window selection tables, door and window selection instructions, general plan of the open section in the southern section, comprehensive decoration plans, floor decoration plans, ceiling decoration plans, wall positioning plans, detailed wastewater pump room practices, sections Diagram, black spraying schematic diagram of public area of property development, detailed drawing of maintenance manhole cover, large-scale drawing of drainage ditch maintenance cover, cable well plugging, skirting line, large-scale drawing of equipment drainage ditch, equipment area foundation, equipment area Large-scale drawings of railings, large-scale drawings of maintenance ladders, large-scale drawings of wall plugging of fire hydrant box holes, large-scale drawings of metal casing through wall plate hole plugging, detailed drawings of aluminum alloy ceilings, and details of short-type open air well protection covers , Metal and non-metal pipeline fire blocking installation drawing, metal air pipe through the floor hole fire block diagram, metal water pipe perforated fire block diagram, metal air pipe with insulation layer, metal water pipe with insulation layer fire floor block diagram , Metal air pipe through wall shrinkage hole fire blocking diagram, large-scale fire block diagram of power holes, anti-static raised floor anti-rat board layout, installation large-scale diagram, equipment area construction column, ring beam, doors and windows Detailed drawings of beams; water supply and drainage instructions, general floor plan for outdoor water supply and drainage, floor plan for sprinkler pipelines, floor plan for water supply and drainage, firefighting plans, floor plan for spraying, sectional views for water supply and drainage, firefighting systems, and water supply and production schematics , Water sprinkler system schematic diagram, large-scale drawing of waste water pump room, system diagram and material table, floor drain installation diagram, large-scale drawing of fire equipment box, outdoor pressure drainage well; power and lighting instructions, low-voltage switchgear arrangement diagram, electrical control Cabinet first and second load arrangement diagram, low-voltage cabinet floor plan, power distribution and grounding plan, lighting distribution plan, evacuation indication and guidance distribution plan, socket and indoor unit power distribution plan, escalator, weak current switch box system Figures, shop main box, shop sub-box system diagram, power distribution box system diagram, station maintenance power box, load switch box system diagram, lighting master box system diagram, emergency lighting cabinet system diagram, lighting circuit control schematic diagram; HVAC description , General plan, Ventilation and air conditioning plan, Ventilation and air conditioning system diagram, Fan installation diagram and so on. Specialties include construction, water supply and drainage, electrical, heating and ventilation.
  • Multi-professional construction drawings of a subway station, the seismic fortification intensity is 7 degrees, the total height of the station is 14.84 meters, the number of stations is 2 floors, and the total construction area is 11,662.48 square meters. The station is a two-story, three-span box structure, the first basement level is the station hall level, and the second basement level is the platform level; the effective platform width of the station is 12 meters, the standard section width of the station is 20.7 meters, and the width of the small-mile end shield shaft section is 24.6. The width of the shield section at the high-mileage end is 25.1 meters; the top of the station is covered with soil about 2 ~ 3.6 meters, and the excavation depth of the foundation pit is about 18.9 meters. There are 2 air ducts and 4 entrances and exits. The contents of the drawing include: architectural description, general plan of the station, main positioning coordinate diagram of the station hall floor, plan plan, longitudinal section, cross section, stairs, lower strand stairs, detailed drawings of the toilet, sewage pump room, large-scale drawing of the wastewater pump room, Large-scale drawing of drainage ditch retaining wall, fire hydrant in-wall installation, detailed drawing of maintenance manhole cover, maintenance ladder, cross-section ditch detailed drawing, anti-flooding protection closed partition door, large-scale drawing of civil defense partition door, shielding door end door Structural layout drawing, section view, hole plan view; water supply and drainage instructions, general outdoor water supply and drainage plan, water supply and drainage plan, station center section, fire water supply system diagram, production and living water system diagram, toilet water supply and drainage system Sample drawings, large-scale drawings of pump rooms, large-scale drawings of pools, sectional views of installation and installation of section pipelines, installation drawings of fixed brackets, detailed drawings of floor drain installation, detailed drawings of station flushing boxes, detailed drawings of fire equipment boxes, detailed outdoor pressure drainage wells Figure, Station civil air defense water supply design during wartime, detailed civil air defense schematic diagram, station civil air defense water supply schematic diagram (D-level chemical control), station civil air defense water supply and drainage block diagram (D-level chemical control), human Schematic diagram of anti-drainage drainage, plan view of personnel entrances and exits during wartime, large-scale drawing of the riser pipes of the rainwater pump room across the civil air defense roof, general diagram of water supply and drainage nodes in the basement of civil air defense; structural description, large-scale beam reinforcement and plane representation, station General plan of main structure, general plan of construction, structural floor plan, reinforcement plan, cross-section structure, general reinforcement structure, main and entrance interface diagram, main and wind pavilion interface diagram, main and shield interval interface diagram, enclosure General plan of the structure, plan of the foundation pit, plan of the supporting plan, elevation views of the left and right side retaining piles of the retaining structure, cross-section views of the retaining structure, diagrams of the retaining structure at the small and large mileage end walls, Station construction process diagram, steel support structure diagram, station foundation pit monitoring diagram; power and lighting instructions, civil air defense plan, civil air defense system diagram, socket power distribution plan, low-voltage main wiring diagram, switch cabinet energy management system diagram, smart meter settings Schematic diagram, switchgear system diagram, low-voltage switchgear plane layout diagram and quantity table, and intelligent low-voltage control system diagram for environmental control electric control cabinet; General description, general plan of station ventilation and air conditioning, schematic diagram of ventilation system, plan of ventilation and air conditioning, plan of ventilation system, plan of small system, schematic diagram of air conditioning water system, plan of station water system, layout of air curtain plane; comprehensive pipeline description, comprehensive pipeline Plan, section and more. Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation, and integrated pipelines.
  • There are many professional construction drawings for a subway station in a city. This station is a 4-layer underground excavation station with a 120-meter side platform. The total length of the station is 149.25 meters, the standard line spacing is 4.6 meters, the standard section width is 20.7 meters, and the total construction area is 7161 square meters. The effective length of the effective platform is 120 meters, and the total length of the shield door is 113 meters. There are 4 entrances and exits in the station, and the lengths of the entrances and exits are not more than 60 meters. The station adopts dual-end delivery and exhaust mode, with 7 groups of wind pavilions, a total of 11; the passenger flow situation of the station: the station's long-term design period is 2041, the long-term peak passenger flow is 35,500 people per hour, and the evening peak hour passenger flow is 32,809. Per hour, the over-peak coefficient is 1.31. The drawings include: power and lighting design instructions, civil air defense electrical design instructions, power distribution system diagrams, power distribution box system diagrams, power distribution floor plans, grounding plans, socket floor plans, lighting floor plans, power distribution box layouts, and low-voltage main wiring Figure, 400V switchgear intelligent low-voltage control system diagram, energy management system diagram, smart meter setup diagram, follow the low-voltage switchgear system diagram, low-voltage switchgear plan layout and quantity table, lighting distribution plan for public areas of the station hall, advertising and Evacuation instruction power distribution plan, guide power distribution plan, station A and B emergency lighting power supply system diagram, intelligent lighting control network diagram, environmental control electrical control cabinet first and second load system diagram; water supply and drainage instructions, outdoor water supply and drainage General floor plan, water supply and drainage, fire floor plan, sectional view, air conditioner room drainage plan, floor plan, fire hydrant system, production and domestic water supply system, main wastewater pump room large-scale detailed drawing, local wastewater pump room large-scale detailed drawing and main Material table, section fire floor plan and system diagram, section pipe layout and installation section view, section pipe fixed bracket installation Figure, floor drain installation schematic diagram of the station hall and platform, floor drain installation detail in the public hall of the station hall, detailed drawing of the station flushing box, detailed drawing of the fire equipment box, detailed drawing of the outdoor pressure drainage well; decoration design description, door and window selection description, general Floor plan, decoration floor plan, general plan of equipment room renovation, black-out schematic plan view, cross-sectional view, axis station floor wall positioning plan, waste water pump room detail view, maintenance manhole cover details, drainage ditch maintenance cover, cable well seal Large-scale diagrams of plugging and skirting; ventilation and air conditioning description, general plan of station ventilation and air conditioning, schematic diagram of tunnel ventilation system, schematic diagram of station large system, floor plan of mezzanine tunnel ventilation system, floor plan of tunnel ventilation system platform, floor plan of equipment of tunnel ventilation system , Plan of jet fan in the tunnel ventilation system, floor plan of the station hall system, air-conditioning room plan, small system schematic, small system plan, equipment management room air-conditioning system renovation, station air-conditioning water system plan, section view, main equipment layout Plan view; comprehensive pipeline description, comprehensive pipeline plan, cross-section view Wait. Specialties include power lighting, water supply and drainage, decoration, HVAC, and integrated pipelines.
  • 某高速公路沿线房建工程服务区结构施工图,包括1、2、3#综合服务楼,维修间,垃圾房及酒店。抗震设防烈度为7度,除垃圾房为砌体结构外,其余单体主要结构形式为钢筋混凝土框架柱结构。其中,酒店和3#综合服务楼地上层数均为2层,建筑高度分别为10.25、14.5米;2、3#综合服务楼、维修间及垃圾房地上层数均为1层,建筑高度为4.69-7.08米。图纸内容含:结构说明,边坡设计总说明,基础设计说明,基础大样图,基础平面布置图,柱平面布置图,结构平面布置图,基础平法施工图,梁板平法施工图,柱平法施工图,楼梯大样图,边坡设计大样图,基础、柱施工图,垃圾房结构施工图,坡屋面梁施工图“平面整体表示方法”制图规则和构造详图,柱表图等等。
  • 某地铁车站结构工程施工图,包括主体结构与围护结构设计。车站形式为地下两层岛式车站(局部三层),本站设置4个出入口和两组风亭。车站总长220.8米,标准段宽度21.2米;车站顶板覆土2.2~4.7米,中心里程处底板埋深17.9米,南端头底板埋深23.3米。车站小里程端接暗挖区间,车站大里程端左线接暗挖区间,右线接盾构区间,双线设盾构接收井。车站除西侧出入口过街段采用矿山法施工外,其余均采用明挖法施工。主体基坑开挖深度16.16~24.19m,采用钻孔灌注桩加内支撑的支护结构型式,桩间网喷混凝土护壁,基坑开挖前需提前进行降水。图纸内容含:设计说明,杂散电流防护设计说明,杂散电流防护钢筋焊接要求,主体结构总平面图,车站施工总平面图,车站左线、车站右线地质纵剖面图,主体基坑支护结构平面布置图,主体基坑钢支撑平面布置图,主体基坑支护结构纵剖面布置图,主体基坑支护结构横剖图,主体基坑支护结构配筋图及构造详图,支撑围檩及接头设计图,车站主体施工步序图,主体施工监测平面图、横剖面图,主体结构底板、中板、顶板平面布置图,负一层中板、夹层板平面布置图,主体结构纵剖面图,中板孔洞及预埋件汇总图,站台板下结构布置平面图,轨顶风道结构布置平面图,主体结构横剖面图,配筋平面图、剖面图,配筋图,楼梯详图,垂直电梯结构及构件详图,出入口与主体接口设计图,风道及出入口与主体接口图,污水池详图,废水池详图,盾构洞口预埋钢环构造图,车站结构钢筋焊接示意图,连接及测量端子安装位置图、焊接安装图,整体道床排流钢筋焊接图,整体道床伸缩缝连接端子焊接安装图,整体道床排流端子焊接安装图等等。
  • 某玻璃加工生产扩建项目低层仓库多专业PDF版施工图(含图审意见回复单),该套图纸为PDF版。抗震设防烈度为7度,主要结构形式为门式钢架结构,建筑高度为9.74米,地上层数1层,总建筑面积为2094.98平方米。图纸内容含:建筑说明,建筑节能设计专篇,平面图,立面图,剖面图,节点大样,门窗大样;给排水说明,雨水系统图,给排水平面图;结构说明,桩基说明,桩位平面布置图,基础承台平面布置图,地坪桩平面布置图,柱平面布置图,柱脚锚栓平面布置图,屋面支撑布置图,屋面结构布置图,墙面立面结构图,钢结构详图,短柱配筋详图,锚栓详图,基础详图;电气说明,电气系统抗震支吊架设计说明,配电系统图,照明平面图,配电及应急照明平面图,屋顶防雷平面图,接地平面图等等。 Majors include architecture, structure, water supply and drainage, and electrical.
  • 某低层厂房全专业施工图,抗震设防烈度为7度,主要结构形式为钢架结构,建筑高度为19.3米(建筑室外地坪到檐口),地上层数2层,局部地上4层,总建筑面积为12863.5平方米,建筑基底占地面积为5980平方米。图纸内容含:建筑说明,平面图,立面图,剖面图,楼梯详图,门窗详图,卫生间详图,节点详图;给排水说明,虹吸雨水系统设计说明、系统图,消火栓系统原理图,给排水大样图、系统图,消防、给排水平面图,屋顶排水平面图;结构说明,钢结构典型焊接大样图,基础平面布置图,地梁、短柱施工图,柱脚锚栓平面布置图,柱脚平面布置图,构件平面布置图,压型钢板布置图及板配筋图,刚架、屋面支撑平面布置图,吊车梁平面布置图,吊车梁及柱间支撑布置图,屋面檩条平面布置图,墙面檩条布置图,节点详图,楼梯详图;电气说明,配电箱系统图,火灾自动报警系统图,配电平面图,照明平面图,消防平面图,防雷接地平面图;暖通说明,通风防排烟平面图。 Majors include architecture, structure, water supply and drainage, electrical, heating and ventilation.
  • This project is a professional construction drawing of a rail transit signal intelligent power industrialization project plant, dormitory, office and gatehouse, pump room building, structure, electrical, HVAC, water supply and drainage. Its dormitory construction area is 2500 square meters, 4 floors above ground. Partial 5 storeys, 16.2 meters high, frame structure; office building, building area 3561 square meters, 4 floors above ground, 16.2 meters high, frame structure; factory building, building area 13,048 square meters, 3 floors above ground, 16.2 meters high, frame structure; Gatehouse, construction area 33 square meters, one floor above ground, 2.8 meters high, brick-concrete structure; pump house, construction area: 25 square meters above ground, 73 square meters underground, building floors: one above ground, one underground 3.3 meters, frame structure. The contents of the drawings include: architectural majors, general floor plans, outdoor engineering general floor plans, outdoor engineering fence vertical sections, construction practice tables, fire protection design articles, construction design instructions, vertical sections, exterior eaves details, stairs details, Detailed drawings of the bathroom, detailed drawings of the elevator in the building; structural specialty, general description of structural design, instructions for the design and construction of prestressed concrete pipe piles in the plant and office building, general instructions for the design of the steel structure of the factory building, beam plan, plate plan, pile plan, foundation plan, foundation details Plans, column plan views, staircase details, exterior eaves details, beam reinforcement drawings, foundation details, structural plans; electrical majors, electrical construction drawing design instructions, legends and weak current system diagrams, electrical system diagrams, lighting plans, socket plans , Fan coil plan, automatic fire alarm and weak current plan, ground plan, lightning protection plan, electrical plan; HVAC specialty, HVAC design and construction instructions, equipment table and large-scale drawings, air-conditioning duct plan, air-conditioning water duct plan, General plan of heating, schematic diagram of direct-fired engine room takeover, ventilation plan, direct-fired engine room Schematic diagram of cooling tower, air-conditioning ventilation plan, electrical general plan, lighting general plan; water supply and drainage specialty, water supply and drainage design and construction instructions, sewage pipeline longitudinal section view, water supply, reclaimed water, outdoor fire protection and sprinkler pipeline plan, outdoor pipeline comprehensive plan, Sewage pipeline plan, rainwater pipeline plan, toilet plan, water supply and drainage and firefighting plan, fire hydrant system plan, water supply and drainage system plan, roof water tank room detailed plan, water supply and drainage plan, sprinkler plan, etc.
  • 某公司厂区建设多栋车间多专业施工图,包括仓库及测试车间、五金加工车间及一个单层车间。测试车间、五金加工车间抗震设防烈度为6度,单层车间抗震设防烈度为7度;主要结构形式分为测试车间、五金加工车间为框架结构,单层车间为钢排架结构。测试车间、五金加工车间地上层数均为3层,建筑高度分别为15.65、14.65米,建筑面积分别为1896.17、1804.18平方米;单层车间建筑高度为12.15米,建筑面积为14464.73平方米。图纸内容含:建筑说明,平面图,立面图,剖面图,楼梯大样图,卫生间详图,节点详图,门窗详图;给排水说明,给排水平面图,高位消防水箱给排水平面图,高位消防水箱给排水系统图,卫生间详图,给水系统图,排水系统图,消火栓给水系统图;结构说明,桩位平面布置图,基础平面布置图,承台详图,配筋平面图,楼梯大样图;电气说明,配电系统图,通讯系统图,有线电视系统图,电力、插座及弱电平面图,照明平面图,防雷平面图,基础接地平面图等等。 Majors include architecture, structure, water supply and drainage, and electrical.
  • Multi-professional preliminary drawings of an energy station and its auxiliary projects (including calculation books, opinion reply sheets, amendment notices, process parts, outdoor pipe network projects), including pump rooms, 2, 4 # parent stations, and 3 substations. The seismic fortification intensity is 7 degrees, and the main structural form is a frame structure. Among them, the building height of the 2 # mother station is 3.45 meters, the height of the underground layer is 7.5 meters, the number of floors above the ground is 1 layer, the number of underground layers is 1 layer, and the total construction area is 1266.21 square meters; The number of floors is 1 layer, with a total construction area of 1807.3 square meters. The building height of the pump room is 28 meters, the number of floors above ground is 1 layer, the number of underground floors is 2 layers, and the total construction area is 1171.5 square meters. The contents of the drawings include: architectural instructions, floor plans, sectional views, stairwell elevations; water supply and drainage instructions, design instructions for fixed gas dry powder fire extinguishing systems, water supply and drainage plans, enlarged views of bathroom water supply and drainage, and water supply and drainage fire protection system schematic , Enlarged view of underground integrated equipment, enlarged view of roof fire water tank; structure description, raft foundation plane layout and reinforcement plan, wall and column layout plan, basement roof structure layout and panel reinforcement plan, basement roof beam Reinforcement plan, large-scale staircase plan; electrical description, power distribution system diagram, gas fire extinguishing system diagram, power plan, lighting plan, fire plan, ground plan, lightning protection plan; HVAC description, ventilation system plan; foundation pit support Description, floor plan of foundation pit support, elevation view, section view, steel flower tube soil nail making, soil nail and spraying surface layer connection, large-scale drawing of hanging net spraying, intercepting drainage ditch, water collecting well, safety fence, Large-scale drawings of drain pipes and monitoring points, floor plan of foundation pit monitoring; HVAC process description, energy station system schematic diagram, pipeline plan, Preparation plan, basic plan, section view, large-scale drawing, schematic diagram of water supply tank takeover; electrical process description, power supply and distribution system schematic, power distribution box system diagram, power control cabinet electrical primary system diagram, electrical floor diagram, grounding plan; automatic control process Description, general diagram of the network structure of the energy control system in the energy supply area of the energy station, point diagram of the automatic control system, schematic diagram of the energy-efficient PLC control cabinet, plan layout of the pipeline of the automatic control system, plan layout of the pipeline of the video monitoring and network telephone system, cable table of the automatic control system, General plan of laying outdoor optical cable pipelines in the energy supply area of energy stations, etc.
  • 某司单层低层设备厂房多专业施工图,包括一配电室。抗震设防烈度为8度,主要结构形式为设备厂房轻型门式钢架结构,配电室砖混结构;设备厂房建筑高度为9.5米,地上层数1层,建筑面积为2304.07平方米,配电室建筑高度为5.25米,地上层数1层,建筑面积为72.63平方米。图纸内容含:建筑说明,平面图,立面图,剖面图;结构说明,螺栓平面布置图,基础平面布置图,基础大样图,部分构造做法图,屋面支撑布置图,屋面檩条布置图,墙面檩条布置图,柱间支撑布置图,山墙檩条及系杆布置图,施工图,屋面板配筋图,圈梁布置图。专业包括建筑、结构。
  • This project is a construction, structure, electrical, weak electricity, HVAC, water supply and drainage, and power construction drawing of a beverage factory relocation and expansion project. The land area is 200,000 square meters, and the total construction area is 234,426 square meters. This set of drawings contains: Main building with a building area of 83210 square meters, 3 floors above ground, 12 meters high; registration room, 4382 square meters, 1 floor above ground, 5.8 meters high; gatehouse and corridor, 244 square meters, 1 floor above ground, 3.3 meters high; Groundwater tank, pump room and boiler room, with a construction area of 780 square meters, a basement level of 6.5 meters high; ammonia press room, 632 square meters, two levels above the ground, 8.5 meters high; wastewater station, 1103 square meters, one level above the ground , 10.5 meters high; solid waste recycling station, 120 square meters, 1 floor above ground, 3.6 meters high; driver's lounge, 67 square meters, 1 floor above ground, 3.6 meters high; bicycle shed, 120 square meters, 1 floor above ground, high 2.2 meters; passenger car parking shed, 1173 square meters, 1 floor above ground, 2.2 meters high; pilot plant, 75,000 square meters, 6 floors above ground, 23 meters high; garage, 8600 square meters, 1 floor above ground, 8 meters high . The contents of the drawings include: architectural majors, building construction design instructions, building energy saving design instructions (main plant, registration room, gatehouse, driver's lounge), room tables (main plant, registration room, gatehouse & corridor, groundwater tank, Pump room & boiler room, ammonia compressor room, solid waste recycling station, driver's lounge, wastewater station), door and window tables, typical node details, general floor plan (first floor), general floor roof plan, vertical and Road map, traffic flow line schematic, fire flow line schematic, road & greening schematic, outdoor road detail, fence detail, trackless cantilever door detail, flagpole detail, building elevation profile, elevator, stair detail, ceiling , Floor, fire zone plan, bathroom detail plan, reclaimed water pump room, fire pump room and pool floor plan, production pool floor plan, stairwell section, etc. and structure, electrical, weak electricity, HVAC, water supply and drainage, power construction drawings And economic and technical indicator table, building energy saving calculation of office building part, registration room building energy saving calculation, doorman building energy saving calculation, driver lounge building energy saving calculation Calculation, calculation report of prescriptive index of public building, thermal performance judgment table of public building envelope structure, calculation of characteristic value of bearing capacity of composite foundation (cement-soil mixing pile), project overview and load calculation, ribbed foundation under wall Models and calculation books such as calculation, load calculation book, dead load, live load, structure, right wind, left wind diagram, corbel calculation, heat load calculation book, etc.
  • 某单层低层车间建筑施工图(无总平面图),设计使用年限均为50年,地上建筑的耐火等级为二级,抗震设防烈度为8度,主要结构形式为钢结构,建筑高度为7.5米,地上层数1层,地上建筑面积为3197平方米。图纸内容含:建筑说明,工程做法表,城市设计专篇,防火设计专篇,车间首层平面图,车间屋顶层平面图,立面图,剖面图,公共卫生间大样图,门窗表,材料做法表,节能备案表。
  • Full-scale professional construction drawing of 202 # workshop of a certain innovation demonstration park, base area: 6936.63 square meters, building area: 55864.63 square meters, fire height: 38 meters, planned height: 38.55 meters, 8 floors above ground, 6 meters above ground, 2 ~ 8 The height of each layer is 4.5 meters, and the structural form is a frame shear wall structure. Contents include building level, elevation, section, location, stairs, bathroom details, wall details, door and window tables and details, decoration practice table, engineering practice table, building description and structure description, foundation construction drawing, column plan Layout drawing, shear wall construction method, beam floor construction method, floor plan construction drawing, staircase detail drawing and water supply and drainage instructions, floor water supply and drainage pipe plan, bathroom water supply and drainage pipe plan enlarged view, domestic water supply and drainage system diagram 、 Hydrant water supply pipe and automatic spraying water supply pipe system diagram and strong and weak electricity description, distribution box system diagram, lighting, electricity plan, lightning protection plan, basic grounding plan, weak electricity system diagram, fire protection, weak electricity plan and HVAC instructions, equipment Table, air-conditioning ventilation plan, air-conditioning water pipe riser system diagram, new fan unit, fan coil pipe takeover details.
  • 该项目为某室外环境景观工程园建、结构、电气、绿化、给排水专业设计施工图,图纸内容含:硬景部分设计说明、景观材料选型定板表、灯具意向图、景观总平面图、景观索引平面图、景观物料平面图、景观标高平面图、景观尺寸平面图、景观坐标平面图、景观方格网放线图、景观小品布置图、通用做法详图、铺装做法详图及井盖详图、垃圾桶详图、前场东侧水景平面图、前场西侧水景平面图、前场西侧水景详图、后场水景平面图、后场水景详图、儿童活动场地平面图、雕塑小品一区域平面图、停车场平面图、连廊平面图、连廊剖、立面详图、下沉休闲区平面图、下沉休闲区详图、前场景墙详图、后场景墙详图、矮墙一、二详图、花池详图、精神堡垒详图、飞碟树池详图、围墙详图、节点平面详图;结构专业,结构设计总说明、前场东侧水景结构图、前场西侧水景结构图、钢结构设计施工说明、廊架基础平面布置图、廊架屋面钢梁平面布置图、后场景墙及水景结构图;电气专业,电气设计说明及主要设备材料表、配电箱系统图、景观照明平面图;绿化部分,绿化施工说明、苗木表、植物网格定位平面图、植物配置平面图、乔木配置平面图、灌木配置平面图、选型意向图;给排水专业,给排水设计说明、绿化灌溉平面图、前场东侧水景给排水平面图、前场东侧水景给水系统原理图、前场西侧水景给排水平面图、前场西侧水景给水系统原理图、后场水景给排水平面图、后场水景给水系统原理图、景观排水平面图、给排水设计节点图、给排水设计大样图等及LED灯带、LED发光模块、LED条形灯带、LED星光灯、草坪灯、池底星星灯、地埋射灯、风灯、户外防水插座、景观灯柱、涌泉灯、给水点硬质化处理示意图、快速取水器、绿化雨水口、线性排水沟效果图及PDF文档等。
  • Construction drawing of a certain landscape improvement project, with a design area of approximately 17,612.35㎡, the project is small, and there is no reuse of building waste. The drawings include: design instructions, park road adjustment area plans, general plans, dimensions, coordinate positioning plans, paving materials. 、 Vertical design plan, grid pay-off location plan, construction enclosure detailed plan, large puddle flower sea floor plan, large puddle garden current base plan, detailed fence plan, planting instructions, regional planting plan, sprinkler irrigation design instructions and large Sample plan, water supply plan, sprinkler control plan, drainage plan
  • Ningxia City's ecological and cultural park project Phase I of the South City water system reconstruction and upgrading project, the main design content is the square within the base area, hard paving, garden sketches and landscape pavilions, corridors and other civil works. Planting of aquatic plants such as lotus flowers, and greening of parks and grounds on both sides of the water system. The total planned land area is about 30.62 hectares, and the water system area is about 11.46 hectares. The contents of the drawings include: general construction instructions, construction instructions for planting parts, greening planting drawings, vertical design drawings, plan positioning plans of relief stone column squares, paving plan views, rough concrete bank views, lotus pond section views, retaining wall elevation views, Detailed drawing of retaining wall section method, park road project quantity table, pavement floor plan, colored concrete laminated pavement method drawing, permeable brick pavement structure layer method drawing, stone pavement structural layer method drawing, bluestone slab and pebble pavement structural layer method drawing, Ting Step plan view, tree pond elevation view, railing detail view, flower stand elevation section view, detail drawing, green planting segmentation schematic diagram and positioning diagram, earthwork calculation diagram, index diagram.
  • Civil hydropower garden model and construction drawing of a model demonstration area, plant part: planting instructions, checklist, general plan of plant configuration, zone index map, tree, shrub and ground cover configuration plan. Hydropower: landscape engineering irrigation, rainwater, drainage, lighting design. Including: water and electricity description, water and drainage plan, lighting, electrical, power system diagram, water and electricity installation details, garden plan lighting layout sideline diagram, Yongquan, villa entrance, mountain water view plan, main entrance water view left, right side plan Illustration. Civil works include: garden construction instructions, general details and model areas, floor plans of parking lots, materials, vertical, index, parts plan views, dimensions, grid line plans and main entrance plans and details, materials, structural plans Arrangement plan, gate plan view, main entrance steel structure plan, materials of the second door area and extension section, index, vertical, line drawing plan, elevation section view, large water view, detailed view of Erdao Mountain Gate, and mountain-shaped water view plane Arrangement plan, elevation and positioning plan, detailed cross-section sample and sales department passage, pay-off plan, step pay-out enlarged plan and detail, steel structure plan, standard section of solid wall railing, waterscape Tingbu flower pond large sample, sale Large-scale roof terrace and villa front yard, laying plan, back yard materials, index, vertical, laying plan, gallery, plan view and detail of the plank road, entrance water feature, door, fence, stone flower Bowl, water curtain, water feature, wrought iron railing, grille, detailed retaining wall detailing, vertical index of large flat floor, laying, material floor plan and small wall, stone bench, detailed view of landscape wall. Contains SKP models and renderings
  • Detailed and construction drawings of various landscape pavilions, including pentagonal pavilions, hexagonal pavilions, octagonal pavilions, octagonal square eaves pavilions, wooden pavilions, Chinese pavilions, European-style pavilions, semi-circular pavilions, semi-circular pavilions, security pavilions, stele pavilions, and single-eave circles Kiosks, leisure kiosks, square kiosks, square mushroom kiosks, antique square kiosks, imitation bamboo kiosks, gazebos, double kiosks, viewing pavilions, water pavilions, gallery pavilions, conjoined double pavilions, umbrella pavilions, fan pavilions, Soviet style pavilions , Convex Pavilion, Wanfo Pavilion, Modern Pavilion, Rectangular Pavilion, Chongyang Lake Yanyu Gallery, etc.
  • This project is the landscape design for the group B and C of the high-rise atrium of Lianfa Phase II. Contents include: design instructions, drawing catalog, general floor plan, index plan, elevation plan, positioning plan, pay-off plan, material plan, general plan railings, wall layout plan, main entrance detail, sentry box detail, characteristic gallery Details, health trail details, viewing platform details, swimming pool elevations, materials, indexes, size drawings, locker room details, gallery details, secondary entrance details, sports park gates, walls details, shop details , Detailed drawings of barrier-free ramps, detailed drawings of ventilation shafts and retaining walls, detailed drawings of children's playgrounds, detailed drawings of the air defense 3 # building, etc.
  • This project is the overall landscape design project of the Beijing Courtyard Villa District, including garden construction, structure, plants, water supply and drainage, electrical, real pictures, SKP model, PDF version of the overall landscape design plan. The drawings include architectural design instructions, entrance dimensions, coordinate plan views, entrance door elevation sectional views, detailed drawings, entrance garage entrance details, water view details on both sides of the entrance, entrance view wall views, drop water details, streams Detailed drawing, detailed drawing of wall, detailed drawing of children's activity square; structural design description, structure drawing of main entrance and secondary entrance door, structural drawing of water view of spectacle wall, structural drawing of water view on both sides of the entrance; design description of water supply and drainage, floor plan of water supply and drainage , System diagram; electrical design description, electrical general floor plan, power distribution system diagram; planting design description, planting general floor plan, real-world photos and so on. (With sales center SKP model, PDF version of the overall landscape design plan).
  • A greening project outside a road in Hexi Industrial Park (2 bids). The drawings include: the general plan of the 2 bids, the pavement plan, the grid positioning and the size plan, the parking lot, the pavement, the curb stone details, the pool, the stool Detailed drawing of tree, tree pond, Tingbu, planting design description, seedling summary table, greening plan; electrical design description, practice sample, distribution box system diagram, pump secondary control schematic diagram, water supply and drainage design description, pool equipment material table And electrical, water supply and drainage plane, the practice is large, the spray equipment according to the conversion plane.
| 注册建筑师 | 注册建造师 | 注册造价师 | 注册结构师 | 注册电气师 All registered divisions | Registered architects | Registered construction divisions | Registered construction divisions | Registered structural divisions | Registered electrical divisions
| 注册规划师 | 注册土木师 | 注册咨询师 | 注册消防师 | 注册化工师 Registered Equipment Engineer | Registered Planner | Registered Civil Engineer | Registered Consultant | Registered Fire Fighter | Registered Chemical Engineer
| 机械设备 | 医药卫生 | 土地测绘 | 水利标准 | 电力专业 | 建材标准 | 船舶运输 All industries | Machinery and equipment | Medicine and health | Land surveying and mapping | Water conservancy standards | Electricity specialty | Building material standards | Shipping and transportation
| 燃气管道 | 煤炭能源 | 石油化工 | 安全环保 | 通信行业 | 计量检定 Railway industry | Gas pipelines | Coal energy | Petrochemical industry | Safety and environmental protection | Communication industry | Measurement verification
推荐图纸 更多>>
  • Multi-professional construction drawings of a super high-rise office building (including project introduction and picture album), the seismic fortification intensity is 7 degrees, the tower is a "dense column frame-core tube" lateral force system, and the upper floor system is a composite floor supported by steel beam System; the basement (except the tower) side-resistance system uses a frame system, the basement floor system is a beam-slab system. The building height is 392.5 meters, the number of above-ground floors is 66, and the number of underground floors is 4. The total construction area is 265040.72 square meters, and the total land area is 15,658.41 square meters. The contents of the drawings include: building description, energy-saving design description, general description of civil air defense design, green building description, axis positioning plan, floor plan, elevation view, landscape greening schematic diagram, awning details, wall node details, civil defense mouth And stairs, floor elevators, escalators, ramp details, wind wells, node details, core tube, bathroom plan, basement machine room, glass sheet steel bridge, VIP Enlarged view of the drop-off area; water supply and drainage instructions, civil air defense and drainage design instructions, external storage pressure heptafluoropropane gas fire extinguishing system design instructions, prefabricated heptafluoropropane gas fire extinguishing system design instructions, outdoor water supply and drainage general plan, domestic water supply and water system schematic diagrams, Sewage and wastewater drainage system schematic diagram, fire hydrant system schematic diagram, automatic sprinkler system schematic diagram, domestic drainage system schematic diagram, water supply and drainage and fire fighting floor plan, automatic sprinkler combination floor plan, civil air defense water supply and drainage system diagram, underground water supply and drainage during wartime Floor plan, gas fire floor plan, toilet water supply and drainage plan, pump room water supply and drainage large-scale drawing; Construction description, civil air defense engineering structure design description, tower structure positioning plan, wall column positioning plan, core tube shear wall section steel positioning plan, pile foundation description and large-scale drawing, pile foundation plan, floor plan, structure plan Figure, Reinforcement diagram, Core tube shear wall section, Column foot joint detail, Ground steel beam embedded parts detail, Cap detail, Wall column positioning plan, Structural template plan, Office supporting structure plan, Art gallery Entrance hall structure plan, large-scale civil air defense entrance and exit, large-scale civil air defense wall and water collecting well, four underground underground civil defense wall pillars, holes in the floor, detailed elevator floor plan, large-scale basement side wall, large-scale fire-fighting pool, driveway plan; Description, 10kV high-voltage power supply system schematic diagram, 10kV high-voltage power distribution system primary wiring diagram, 10kV high-voltage substation equipment layout, ground plan, 10kV high-voltage substation wiring layout, 10kV high-voltage substation cross-section view, distribution trunk System diagram, power distribution system diagram, equipment layout plan, wiring layout diagram, section view, lighting plan, power plan, distribution box system diagram, power supply system diagram, Ray described grounding system and large drawing, a schematic diagram of a ground system, lightning protection system schematic plan view of a ground mine like. Majors include architecture, structure, water supply and drainage, and electrical.
  • This project is a construction project of a commercial square in Ningxia. The building has 15 floors, one underground, a building height of 59.6 meters, a building area of 14,546 square meters, a structural form of a frame structure, and a design life of 50 years. The drawings include architectural descriptions, vertical sectional views, floor and elevator details, bathroom details, doors and windows details; structural descriptions, shear wall, column plan views, edge member node diagrams, beam and plate reinforcement diagrams, and staircase details; Water supply and drainage instructions, water supply and drainage, firefighting, sprinkler floor plans, private rooms, apartment water supply and drainage large-scale drawings, water supply and drainage, fire hydrants, sprinkler system diagrams; HVAC instructions, heating, heating mains, ventilation smoke exhaust plan, system diagrams; Electrical description, main line, lighting, weak current and fire door monitoring, automatic fire alarm, lightning protection and ground plan, system diagram.
  • 某景观提升工程施工图,设计面积约17612.35㎡,该项目较小,无建筑废弃再生品利用,图纸包含:设计说明,园路调整区域平面图,总平面图,尺寸标注、坐标定位平面图,铺装材料、竖向设计平面图,网格放线定位平面图,施工围挡详图,大水坑花海底图,大水坑花园现状底图,栅栏详图,种植说明,区域种植平面图,喷灌设计说明及大样图,给水平面图,喷灌控制平面图,排水平面图
  • The project is a four-storey catering business center in Xi'an, Shaanxi. The building area is 19,623.87 square meters. The building structure is a steel frame structure. The building structure safety system is Grade II. The seismic fortification intensity is 7 degrees. The drawing includes architectural design instructions, floor plans, elevations, section views, and detailed drawings of each floor; structural design instructions, foundation floor plan, floor beam and plate reinforcement drawings at each floor, column bolt layout, and node details; Drainage design description, floor water supply and drainage plan, spray floor plan, water supply and drainage system diagram, hydrant, self-spraying system diagram; HVAC design description, air-conditioning air plan of each floor, air-level water plan of each floor, system diagram, etc.